Plate or Arthroplasty for complex Mason Type-III Radial Head Fractures? Mid-to-long term results from a blinded outcome assessor study
This study provides evidence that 3- and 4-part Mason type III fractures are prone to plate osteosynthesis. In contrast, greater than 4-part fractures can more reliably be treated by replacement. This leads to a proposed increase in fragment numbers to four, where ORIF most likely leads to good clinical results. However, in patients with 4+ fragment patterns, ORIF did not show statistically significantly worse results concerning the collected clinical values. This study supports the use of the ORIF approach to save the radial head.
Authors
- Christina J. Lorenz (ORCID: https://orcid.org/0000-0002-7985-8119)
- Claus‐Christian Carbon (ORCID: https://orcid.org/0000-0002-3446-9347)
- Rainer H. Meffert (ORCID: https://orcid.org/0000-0002-6667-3262)
- Lars Eden
Institutions
- University Hospital of Zurich (CH)
- Universitätsklinikum Würzburg (DE)
- University of Bamberg (DE)
Publication Details
- Journal
- Injury
- Published
- 2024-11-07
- DOI
- https://doi.org/10.1016/j.injury.2024.111981
- Citations
- 6
- Primary Topic
- Elbow and Forearm Trauma Treatment
- Type
- article
- Field-Weighted Citation Impact
- 1.50