Reducing electrocardiographic interference in the multichannel electromyogram to help muscle fatigue assessment in low-intensity contractions

• EMG signals collected close to the heart may contain significant ECG interference. • This may hamper muscle fatigue evaluation, especially for low-contraction levels. • Methodology developed for reducing interference using template subtraction and ICA. • ECG components are automatically identified and no additional channel is required. • Low-frequency spectral content is preserved, which is valuable in fatigue analysis. Surface electromyography (EMG) can be used in the rehabilitation of musculoskeletal disorders, for evaluating the coordination of muscles that stabilize a joint, or as an objective tool in assessing muscle fatigue. This latter may be achieved by evaluating the low-frequency content of the EMG. However, the electrocardiogram (ECG) interference is also recorded when EMG is acquired close to the heart. It may mask or even modify the information of interest in the EMG. Different signal processing techniques have been proposed to eliminate ECG artifacts from the EMG signals, the high-pass filter being the most used one. Nevertheless, this classic filtering approach would also attenuate EMG activities below 30 Hz, which contain information from low-intensity muscle contractions. This work addresses the automatic ECG attenuation when multichannel EMG is collected on the left pectoralis major muscle during a muscle fatigue test. The proposed ECG artifact mitigation extends a successful automatic template subtraction (TS) approach, which does not require an extra reference channel and is now applied to independent EMG source signal components extracted using a blind source separation technique (ICA, Independent Component Analysis). The automatic detection of ECG components was performed through two alternative measures: entropy and Kullback-Leibler divergence. While the ECG interference seems to hamper the detection of muscle fatigue in the low-contraction regime, the association ICA+TS preserved better the EMG low-frequency content, and the entropy-based automatic detection was found to be more suitable, avoiding possible errors that might arise from manual detection procedures.

Authors

Institutions

Publication Details

Journal
Franklin Open
Published
2024-11-07
DOI
https://doi.org/10.1016/j.fraope.2024.100177
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reducing electrocardiographic interference in the multichannel electromyogram to help muscle fatigue assessment in low-intensity contractions

Antonio Mauricio Ferreira Leite Miranda de Sá, J. M. Seixas, José Dilermando Costa
Franklin Open
Muscle activation and electromyography studies
article

Reducing electrocardiographic interference in the multichannel electromyogram to help muscle fatigue assessment in low-intensity contractions

Antonio Mauricio Ferreira Leite Miranda de Sá, J. M. Seixas, José Dilermando Costa
article en

Abstract

• EMG signals collected close to the heart may contain significant ECG interference. • This may hamper muscle fatigue evaluation, especially for low-contraction levels. • Methodology developed for reducing interference using template subtraction and ICA. • ECG components are automatically identified and no additional channel is required. • Low-frequency spectral content is preserved, which is valuable in fatigue analysis. Surface electromyography (EMG) can be used in the rehabilitation of musculoskeletal disorders, for evaluating the coordination of muscles that stabilize a joint, or as an objective tool in assessing muscle fatigue. This latter may be achieved by evaluating the low-frequency content of the EMG. However, the electrocardiogram (ECG) interference is also recorded when EMG is acquired close to the heart. It may mask or even modify the information of interest in the EMG. Different signal processing techniques have been proposed to eliminate ECG artifacts from the EMG signals, the high-pass filter being the most used one. Nevertheless, this classic filtering approach would also attenuate EMG activities below 30 Hz, which contain information from low-intensity muscle contractions. This work addresses the automatic ECG attenuation when multichannel EMG is collected on the left pectoralis major muscle during a muscle fatigue test. The proposed ECG artifact mitigation extends a successful automatic template subtraction (TS) approach, which does not require an extra reference channel and is now applied to independent EMG source signal components extracted using a blind source separation technique (ICA, Independent Component Analysis). The automatic detection of ECG components was performed through two alternative measures: entropy and Kullback-Leibler divergence. While the ECG interference seems to hamper the detection of muscle fatigue in the low-contraction regime, the association ICA+TS preserved better the EMG low-frequency content, and the entropy-based automatic detection was found to be more suitable, avoiding possible errors that might arise from manual detection procedures.

Franklin OpenVol. 9
Universidade Federal do Rio de Janeiro (BR)
Openalex Percentile: Top 82%
Muscle activation and electromyography studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.