Evaluation of novel respiratory sensor in neonatal respiratory monitoring

<bold>Introduction:</bold> There is a need to improve respiratory monitoring for neonatal patients, enabling detection of apnoeas and clinical deterioration. New wearable technology is being developed using artificial intelligence to enhance diagnostic accuracy. <bold>Objectives:</bold> Pre-clinical evaluation of a novel, accelerometer-based respiratory sensor (Pneumowave, Pneumowave Ltd, UK) to capture clinically relevant extremes of respiratory parameters in neonatal patients. <bold>Methods:</bold> Pneumowave sensor was placed on a term neonatal mannequin’s chest during a protocol of mechanical ventilation settings. MATLAB allowed accelerometer waveforms to be visualised across a range of breathing frequencies (RR) and tidal volumes (TVs), inspiratory: expiratory ratios, biosensor positions and apnoea simulation. Accelerometer data was compared to ventilator-measured parameters and Pneumowave algorithm predicted RRs. <bold>Results:</bold> Algorithm RR was compared to visual count RR, for ventilator frequencies 3-75 breaths per minute (bpm), R<sup>2</sup> 0.05549, P 0.3798, Bland-Altman plot bias –15.13, 95% CI [–68.9-36.68]. Removing outliers, ventilator frequencies 20-60bpm demonstrated a strong statistically significant correlation, R<sup>2</sup> 0.9372, P <0.0001, Bland-Altman plot bias –1.66, 95% CI [–8.56 to 5.45]. RR was accurately identified, +/-2bpm, for ventilator delivered tidal volumes of ≥7.6ml, with accuracy dropping for tidal volume ≤6ml, Bland-Altman plot bias of –9.11, 95% CI [−43.45-25.22]. <bold>Conclusion:</bold> Pneumowave biosensor can accurately measure RR and pattern across a range of neonatal applicable breathing frequencies and TVs. Further research will develop the sensitivity and specificity of algorithms for monitoring respiratory metrics in neonatal patients.

Authors

Institutions

Publication Details

Published
2024-09-14
DOI
https://doi.org/10.1183/13993003.congress-2024.pa2101
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of novel respiratory sensor in neonatal respiratory monitoring

Catriona Cowan, Neil P Patel, Hannah Vennard, Osian Meredith et al.
Non-Invasive Vital Sign Monitoring
article

Evaluation of novel respiratory sensor in neonatal respiratory monitoring

Catriona Cowan, Neil P Patel, Hannah Vennard, Osian Meredith, P. S. W. Davies, Ross Langley, Jennifer Miller
article en

Abstract

<bold>Introduction:</bold> There is a need to improve respiratory monitoring for neonatal patients, enabling detection of apnoeas and clinical deterioration. New wearable technology is being developed using artificial intelligence to enhance diagnostic accuracy. <bold>Objectives:</bold> Pre-clinical evaluation of a novel, accelerometer-based respiratory sensor (Pneumowave, Pneumowave Ltd, UK) to capture clinically relevant extremes of respiratory parameters in neonatal patients. <bold>Methods:</bold> Pneumowave sensor was placed on a term neonatal mannequin’s chest during a protocol of mechanical ventilation settings. MATLAB allowed accelerometer waveforms to be visualised across a range of breathing frequencies (RR) and tidal volumes (TVs), inspiratory: expiratory ratios, biosensor positions and apnoea simulation. Accelerometer data was compared to ventilator-measured parameters and Pneumowave algorithm predicted RRs. <bold>Results:</bold> Algorithm RR was compared to visual count RR, for ventilator frequencies 3-75 breaths per minute (bpm), R<sup>2</sup> 0.05549, P 0.3798, Bland-Altman plot bias –15.13, 95% CI [–68.9-36.68]. Removing outliers, ventilator frequencies 20-60bpm demonstrated a strong statistically significant correlation, R<sup>2</sup> 0.9372, P <0.0001, Bland-Altman plot bias –1.66, 95% CI [–8.56 to 5.45]. RR was accurately identified, +/-2bpm, for ventilator delivered tidal volumes of ≥7.6ml, with accuracy dropping for tidal volume ≤6ml, Bland-Altman plot bias of –9.11, 95% CI [−43.45-25.22]. <bold>Conclusion:</bold> Pneumowave biosensor can accurately measure RR and pattern across a range of neonatal applicable breathing frequencies and TVs. Further research will develop the sensitivity and specificity of algorithms for monitoring respiratory metrics in neonatal patients.

Royal Hospital for Children (GB), Digital Preservation Coalition (United Kingdom) (GB), University of Glasgow (GB)
Good health and well-being
Openalex Percentile: Top 82%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.