Respiratory oscillometry in infants: methodological aspects

<bold>Background:</bold> Oscillometry in infant lung function is of emerging potential but is challenged by special conditions (sleep, position, nasal breathing and high mechanical impedance) not encountered in older age groups. <bold>Aims:</bold> To investigate the effects of face mask positioning and head support on respiratory impedance (Zrs) in infants. <bold>Methods:</bold> Sedated infants (n=21) who were born preterm (25-37 wk gestational age) were evaluated longitudinally as outpatients at corrected-ages of 5-6 (visit 1; V1) and 12 months (V2). A device in development (N-100; Thorasys Inc., Montreal, CA) was employed to measure Zrs in the 7-41-Hz range. The head/mask support was accomplished with 1 hand (1H) or 2 hands (2H); >3 regular segments of 7 s were collected in each condition. The Zrs spectra were processed to correct (corr) for the face mask shunt. Mean resistance (R), compliance (C), and resonance frequency (fres) were estimated via model fitting. <bold>Results:</bold> Uncorrected Zrs failed to exhibit fres in 12 (V1) and 1 (V2) subjects and resulted in unexpectedly low C values. V1 and V2 results reflected growth (Table 1). There was no significant difference in any measure with 1H and 2H support (signed rank test). <table-wrap><object-id>erj;64/suppl_68/PA1462/TB1</object-id><object-id>T1</object-id><object-id>TB1</object-id><table><colgroup><col></col><col></col><col></col><col></col><col></col></colgroup><tbody><tr><td></td><td>V1</td><td>V1corr</td><td>V2</td><td>V2corr</td></tr><tr><td>R (cmH<sub>2</sub>O.s/L)</td><td>31.9 [27.2;36.3]</td><td>33.4 [28.9;39.2]*</td><td>25.7 [19.8;29.8]<sup># †</sup></td><td>23.2 [19.7;27.5]* <sup>††</sup></td></tr><tr><td>C (mL/cmH<sub>2</sub>O)</td><td>1.08 [0.86;1.32]</td><td>1.56 [1.13;1.90]**</td><td>1.62 [1.23;2.10]<sup># †</sup></td><td>1.89 [1.56;2.84]** <sup>†</sup></td></tr><tr><td>fres (Hz)</td><td>53.1 [39.3;61.0]</td><td>17.6 [16.1;23.6]*</td><td>28.6 [23.1;37.8]<sup>#</sup></td><td>16.4 [13.4;18.0]** <sup>†</sup></td></tr></tbody></table></table-wrap> Table 1. Median [25%;75%] values of Zrs measures. <italic>p</italic> corr <italic>vs</italic> uncorr: <0.05*, <0.001**; V2 <italic>vs</italic> V1: <0.05<sup>†</sup>, <0.001<sup>††</sup> <bold>Conclusion:</bold> Correction for the face mask shunt impedance provided more realistic Zrs spectra and derived measures, especially at high Zrs values.

Authors

Institutions

Publication Details

Published
2024-09-14
DOI
https://doi.org/10.1183/13993003.congress-2024.pa1462
Primary Topic
Human Health and Disease
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Respiratory oscillometry in infants: methodological aspects

Christina Tiller, Laura Amos, Zoltán Hantos, Jeffrey Bjerregaard et al.
Human Health and Disease
article

Respiratory oscillometry in infants: methodological aspects

Christina Tiller, Laura Amos, Zoltán Hantos, Jeffrey Bjerregaard, Gergely Makan, Robert I. Tepper
article en

Abstract

<bold>Background:</bold> Oscillometry in infant lung function is of emerging potential but is challenged by special conditions (sleep, position, nasal breathing and high mechanical impedance) not encountered in older age groups. <bold>Aims:</bold> To investigate the effects of face mask positioning and head support on respiratory impedance (Zrs) in infants. <bold>Methods:</bold> Sedated infants (n=21) who were born preterm (25-37 wk gestational age) were evaluated longitudinally as outpatients at corrected-ages of 5-6 (visit 1; V1) and 12 months (V2). A device in development (N-100; Thorasys Inc., Montreal, CA) was employed to measure Zrs in the 7-41-Hz range. The head/mask support was accomplished with 1 hand (1H) or 2 hands (2H); >3 regular segments of 7 s were collected in each condition. The Zrs spectra were processed to correct (corr) for the face mask shunt. Mean resistance (R), compliance (C), and resonance frequency (fres) were estimated via model fitting. <bold>Results:</bold> Uncorrected Zrs failed to exhibit fres in 12 (V1) and 1 (V2) subjects and resulted in unexpectedly low C values. V1 and V2 results reflected growth (Table 1). There was no significant difference in any measure with 1H and 2H support (signed rank test). <table-wrap><object-id>erj;64/suppl_68/PA1462/TB1</object-id><object-id>T1</object-id><object-id>TB1</object-id><table><colgroup><col></col><col></col><col></col><col></col><col></col></colgroup><tbody><tr><td></td><td>V1</td><td>V1corr</td><td>V2</td><td>V2corr</td></tr><tr><td>R (cmH<sub>2</sub>O.s/L)</td><td>31.9 [27.2;36.3]</td><td>33.4 [28.9;39.2]*</td><td>25.7 [19.8;29.8]<sup># †</sup></td><td>23.2 [19.7;27.5]* <sup>††</sup></td></tr><tr><td>C (mL/cmH<sub>2</sub>O)</td><td>1.08 [0.86;1.32]</td><td>1.56 [1.13;1.90]**</td><td>1.62 [1.23;2.10]<sup># †</sup></td><td>1.89 [1.56;2.84]** <sup>†</sup></td></tr><tr><td>fres (Hz)</td><td>53.1 [39.3;61.0]</td><td>17.6 [16.1;23.6]*</td><td>28.6 [23.1;37.8]<sup>#</sup></td><td>16.4 [13.4;18.0]** <sup>†</sup></td></tr></tbody></table></table-wrap> Table 1. Median [25%;75%] values of Zrs measures. <italic>p</italic> corr <italic>vs</italic> uncorr: <0.05*, <0.001**; V2 <italic>vs</italic> V1: <0.05<sup>†</sup>, <0.001<sup>††</sup> <bold>Conclusion:</bold> Correction for the face mask shunt impedance provided more realistic Zrs spectra and derived measures, especially at high Zrs values.

Semmelweis University (HU), University of Indianapolis (US), University of Szeged (HU), Indiana University – Purdue University Indianapolis (US)
Zero hunger
Openalex Percentile: Top 69%
Human Health and Disease
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.