Assessing the potential accuracy of a small-sized goniometer with extended dynamic range based on nuclear magnetic resonance

This paper evaluates potential accuracy characteristics of a small-sized goniometer based on nuclear magnetic resonance with an extended dynamic range. This required constructing a model of goniometer errors, estimating its accuracy based on this model, and formulating practical recommendations for the design of such a device based on the accuracy assessment. To evaluate the accuracy of a nuclear goniometer, a theoretical model was built that makes it possible to determine the optimal operating parameters of the cell gas mixture, the ranges of their permissible changes, the sensitivity of the goniometer, and the dependence of its characteristics on external and internal factors. In particular, the dependence of output signal of the device on the parameters of gas mixture and optical pumping has been determined. For a goniometer with a cell volume of 8 cm3, the optimum temperature is 130 °C, and the optimum intensity of the pumping radiation is 5 mW. The dependence of output signal on the measured angle of rotation was also established, as well as the noise and error dependence of the device on the permissible values of its parameters. Based on the model built, parameters of a goniometer with a cell volume of 8 cm3 were determined; the maximum angular sensitivity of such a goniometer with complete suppression of technical noise is δφsen=1.0 arcsec. The greatest contribution to the angle measurement error is from the instability of pumping power Ip (ΔIp/Ip=0.05) – 85 %, magnetic field B0 (ΔB0/B0=10-8) – 13 %, temperature T (ΔT/T=0,1) – 2 %. The goniometer under consideration corresponds to the medium accuracy class, δφtot≥10 arcsec. It could be used in optical manufacturing for operational control, calibration, and certification of optical products. To improve the angular accuracy of the goniometer, it is necessary to increase the stability of the laser pumping intensity

Authors

Publication Details

Journal
Eastern-European Journal of Enterprise Technologies
Published
2024-10-31
DOI
https://doi.org/10.15587/1729-4061.2024.313878
Primary Topic
Body Composition Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessing the potential accuracy of a small-sized goniometer with extended dynamic range based on nuclear magnetic resonance

Sergiy Ivanov
Eastern-European Journal of Enterprise Technologies
Body Composition Measurement Techniques
article

Assessing the potential accuracy of a small-sized goniometer with extended dynamic range based on nuclear magnetic resonance

Sergiy Ivanov
article en

Abstract

This paper evaluates potential accuracy characteristics of a small-sized goniometer based on nuclear magnetic resonance with an extended dynamic range. This required constructing a model of goniometer errors, estimating its accuracy based on this model, and formulating practical recommendations for the design of such a device based on the accuracy assessment. To evaluate the accuracy of a nuclear goniometer, a theoretical model was built that makes it possible to determine the optimal operating parameters of the cell gas mixture, the ranges of their permissible changes, the sensitivity of the goniometer, and the dependence of its characteristics on external and internal factors. In particular, the dependence of output signal of the device on the parameters of gas mixture and optical pumping has been determined. For a goniometer with a cell volume of 8 cm3, the optimum temperature is 130 °C, and the optimum intensity of the pumping radiation is 5 mW. The dependence of output signal on the measured angle of rotation was also established, as well as the noise and error dependence of the device on the permissible values of its parameters. Based on the model built, parameters of a goniometer with a cell volume of 8 cm3 were determined; the maximum angular sensitivity of such a goniometer with complete suppression of technical noise is δφsen=1.0 arcsec. The greatest contribution to the angle measurement error is from the instability of pumping power Ip (ΔIp/Ip=0.05) – 85 %, magnetic field B0 (ΔB0/B0=10-8) – 13 %, temperature T (ΔT/T=0,1) – 2 %. The goniometer under consideration corresponds to the medium accuracy class, δφtot≥10 arcsec. It could be used in optical manufacturing for operational control, calibration, and certification of optical products. To improve the angular accuracy of the goniometer, it is necessary to increase the stability of the laser pumping intensity

Eastern-European Journal of Enterprise TechnologiesVol. 5(5 (131))
Affordable and clean energy
Openalex Percentile: Top 73%
Body Composition Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.