Identification of characteristics of conceptual prototype of microprocessor resource-saving relay protection system

The object of the study is the conceptual prototype of a microprocessor resource-saving relay protection system. Currently, relay protection ensures electrical networks reliable and efficient work, however, the traditional architecture is proprietary, not allowing to fix and replace damaged parts without a company specialist. Therefore, the open-architecture relay protection is a very pressing issue, but the problem lies in meeting the relay protection requirements. The data transmission protocols nRF and ESP-NOW, Hall sensors evaluation for AC current measurement determination and sensor accuracy improvement was implemented. Experimental validation demonstrated that nRF and ESP-NOW protocols meet the delay and reliability requirements, however, the nRF protocol is more suitable due to its flexibility and obstacle penetration. The data demonstrated that the most effective conditions are without obstacles at 15 meters from the modem and with obstacles 5 meters from the modem. The experiment of Hall sensors characteristics determination demonstrated the accuracy of current measurement with the set values of the opening and closing currents. Nevertheless, it is not accurate (12.45 %) for the relay protection application. Therefore, the application of the changing values of the opening and closing currents is more effective and accuracy reaches 6.92 %. As a result, the service life of the Hall sensor was determined, and even after 10 million openings, the open state time remained unchanged. Therefore, the approximation function for current amplitude determination depending on open state time was found. On the other hand, Hall sensors may suffer from temperature drift and require further optimization to be fully reliable. The study limitation is the current range from 0 to 800 A

Authors

Institutions

Publication Details

Journal
Eastern-European Journal of Enterprise Technologies
Published
2024-10-31
DOI
https://doi.org/10.15587/1729-4061.2024.312489
Citations
1
Primary Topic
VLSI and Analog Circuit Testing
Type
article
Field-Weighted Citation Impact
0.49
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Identification of characteristics of conceptual prototype of microprocessor resource-saving relay protection system

O. K. Abdirashev, Ilyas Kazambayev, Lalita Kirichenko, Alexandr V. Neftissov et al.
1 citations
Eastern-European Journal of Enterprise Technologies
VLSI and Analog Circuit Testing
0.49
article

Identification of characteristics of conceptual prototype of microprocessor resource-saving relay protection system

O. K. Abdirashev, Ilyas Kazambayev, Lalita Kirichenko, Alexandr V. Neftissov, Andrii O. Biloshchytskyi, Dnislam Urazayev
article en
1 citations

Abstract

The object of the study is the conceptual prototype of a microprocessor resource-saving relay protection system. Currently, relay protection ensures electrical networks reliable and efficient work, however, the traditional architecture is proprietary, not allowing to fix and replace damaged parts without a company specialist. Therefore, the open-architecture relay protection is a very pressing issue, but the problem lies in meeting the relay protection requirements. The data transmission protocols nRF and ESP-NOW, Hall sensors evaluation for AC current measurement determination and sensor accuracy improvement was implemented. Experimental validation demonstrated that nRF and ESP-NOW protocols meet the delay and reliability requirements, however, the nRF protocol is more suitable due to its flexibility and obstacle penetration. The data demonstrated that the most effective conditions are without obstacles at 15 meters from the modem and with obstacles 5 meters from the modem. The experiment of Hall sensors characteristics determination demonstrated the accuracy of current measurement with the set values of the opening and closing currents. Nevertheless, it is not accurate (12.45 %) for the relay protection application. Therefore, the application of the changing values of the opening and closing currents is more effective and accuracy reaches 6.92 %. As a result, the service life of the Hall sensor was determined, and even after 10 million openings, the open state time remained unchanged. Therefore, the approximation function for current amplitude determination depending on open state time was found. On the other hand, Hall sensors may suffer from temperature drift and require further optimization to be fully reliable. The study limitation is the current range from 0 to 800 A

Eastern-European Journal of Enterprise TechnologiesVol. 5(5 (131))
L. N. Gumilyov Eurasian National University (KZ), Astana Medical University (KZ), Nazarbayev University (KZ)
Openalex Percentile: Top 35%
VLSI and Analog Circuit Testing
0.49
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.