Evaluation of diode laser for excision of canine cutaneous tumours

The study was conducted for evaluation and comparison of single and dual wavelength of diode laser with conventional excision of cutaneous tumours in dogs. 12 dogs suffering from cutaneous tumours were divided in 3 groups each consist of 4 dogs. In group I excision of tumours done by conventional scalpel method, in group II excision of tumours done by diode laser at wavelength 980 nm and power 10 W. In group III excision of tumours done by diode laser at dual wavelength (810 nm + 980 nm) and power 10-12 W. Incisional quality was observed excellent in group I without charring followed group III and group II along with charring of incised margins. On histopathological examination, incised skin margins in group I observed regular well defined with intact epidermis and dermis. In group II the margins were irregular with moderate charring. In group III the margins were irregular with severe charring. The mean values of intraoperative bleeding were reduced significantly (p<0.05) in group II and group III as compared to group I. The mean values of time required for complete excision of tumour was reduced significantly (p<0.05) in group II and group III as compared to group I The mean values of wound assessment score reduced significantly (p< 0.05) in group I from day 3 to 14. Duration of wound healing was reduced significantly (p<0.05) in group I and group II as compared to group III. Scar score showed significant (p<0.05) difference between group I and group III on day 14 and 21 postoperatively. It was concluded that diode laser at 980 nm on 10 W and diode laser at 810 nm + 980 nm on 10-12 W were found superior than scalpel in terms of minimal intraoperative bleeding and less time utilized for excision of tumours.

Authors

Publication Details

Journal
International Journal of Advanced Biochemistry Research
Published
2024-10-01
DOI
https://doi.org/10.33545/26174693.2024.v8.i10sr.2762
Primary Topic
Veterinary Oncology Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of diode laser for excision of canine cutaneous tumours

Shobha Jawre, Babita Das, Apoorva Mishra, Apra Shahi et al.
International Journal of Advanced Biochemistry Research
Veterinary Oncology Research
article

Evaluation of diode laser for excision of canine cutaneous tumours

Shobha Jawre, Babita Das, Apoorva Mishra, Apra Shahi, Yamini Verma, Surbhi Bunker, Rakesh Kumar Barhaiya, Randhir Singh Chouhan
article en

Abstract

The study was conducted for evaluation and comparison of single and dual wavelength of diode laser with conventional excision of cutaneous tumours in dogs. 12 dogs suffering from cutaneous tumours were divided in 3 groups each consist of 4 dogs. In group I excision of tumours done by conventional scalpel method, in group II excision of tumours done by diode laser at wavelength 980 nm and power 10 W. In group III excision of tumours done by diode laser at dual wavelength (810 nm + 980 nm) and power 10-12 W. Incisional quality was observed excellent in group I without charring followed group III and group II along with charring of incised margins. On histopathological examination, incised skin margins in group I observed regular well defined with intact epidermis and dermis. In group II the margins were irregular with moderate charring. In group III the margins were irregular with severe charring. The mean values of intraoperative bleeding were reduced significantly (p<0.05) in group II and group III as compared to group I. The mean values of time required for complete excision of tumour was reduced significantly (p<0.05) in group II and group III as compared to group I The mean values of wound assessment score reduced significantly (p< 0.05) in group I from day 3 to 14. Duration of wound healing was reduced significantly (p<0.05) in group I and group II as compared to group III. Scar score showed significant (p<0.05) difference between group I and group III on day 14 and 21 postoperatively. It was concluded that diode laser at 980 nm on 10 W and diode laser at 810 nm + 980 nm on 10-12 W were found superior than scalpel in terms of minimal intraoperative bleeding and less time utilized for excision of tumours.

International Journal of Advanced Biochemistry ResearchVol. 8(10S)
Openalex Percentile: Top 64%
Veterinary Oncology Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.