Plasma Tailoring of NH<sub>2</sub>-MIL-53 with Enhanced Fluorescence Emission for Simultaneous Detection of Multiple Heavy Metals in Water

Indium, copper, and mercury are important raw materials in the electronics industry and often coexist in factory wastewater. Therefore, the development of a highly sensitive and selective method for the simultaneous detection of these heavy metal ions is of great significance for water quality monitoring and environmental protection. Herein, we report a NH<sub>2</sub>-MIL-53 fluorescent probe for the simultaneous detection of trace In<sup>3+</sup>, Cu<sup>2+</sup>, and Hg<sup>2+</sup> in water. After a low-temperature NH<sub>3</sub> plasma tailoring treatment for grafting electron-donor amine groups, the obtained NH<sub>2</sub>-MIL-53-M exhibited enhanced fluorescence emission intensity (∼6 times) coupled with selective adsorption of In<sup>3+</sup>, Cu<sup>2+</sup>, and Hg<sup>2+</sup>. This quenched the NH<sub>2</sub>-MIL-53-M fluorescence and allowed to significantly increase the selectivity and sensitivity for detection of In<sup>3+</sup>, Cu<sup>2+</sup>, and Hg<sup>2+</sup>. The fluorescence quenching constant (<i>K</i><sub>sv</sub>) values were 2.23 × 10<sup>5</sup>, 1.00 × 10<sup>5</sup>, and 2.74 × 10<sup>4</sup> M<sup>-1</sup>, while the limit of detection (LODs) values were 0.06, 0.14, and 0.53 μM, for In<sup>3+</sup>, Cu<sup>2+</sup>, and Hg<sup>2+</sup>, respectively. The concentrations of In<sup>3+</sup>, Cu<sup>2+</sup>, and Hg<sup>2+</sup> in real environmental samples could be determined by addition of appropriate masking agents, and the recoveries were within the range of 94-110%. This study not only supplied a strategy for constructing a highly sensitive and selective fluorescent probe but also established a platform for simultaneous detection of multiple heavy metal ions in water.

Authors

Institutions

Publication Details

Journal
ACS Applied Materials & Interfaces
Published
2024-11-05
DOI
https://doi.org/10.1021/acsami.4c09330
Citations
10
Primary Topic
Mercury impact and mitigation studies
Type
article
Field-Weighted Citation Impact
3.15

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Plasma Tailoring of NH2-MIL-53 with Enhanced Fluorescence Emission for Simultaneous Detection of Multiple Heavy Metals in Water

Huanting Wang, Xianbiao Wang, Songqin Liu, Soufian Chakir et al.
10 citations
ACS Applied Materials & Interfaces
Mercury impact and mitigation studies
3.15
article

Plasma Tailoring of NH2-MIL-53 with Enhanced Fluorescence Emission for Simultaneous Detection of Multiple Heavy Metals in Water

Huanting Wang, Xianbiao Wang, Songqin Liu, Soufian Chakir, Zhigao Huang, Yangyang Zhao, Daosheng Sun, Yaru Li, Yu Ding, Yongfei Xu, Yuyang Hu
article en
10 citations

Abstract

Indium, copper, and mercury are important raw materials in the electronics industry and often coexist in factory wastewater. Therefore, the development of a highly sensitive and selective method for the simultaneous detection of these heavy metal ions is of great significance for water quality monitoring and environmental protection. Herein, we report a NH<sub>2</sub>-MIL-53 fluorescent probe for the simultaneous detection of trace In<sup>3+</sup>, Cu<sup>2+</sup>, and Hg<sup>2+</sup> in water. After a low-temperature NH<sub>3</sub> plasma tailoring treatment for grafting electron-donor amine groups, the obtained NH<sub>2</sub>-MIL-53-M exhibited enhanced fluorescence emission intensity (∼6 times) coupled with selective adsorption of In<sup>3+</sup>, Cu<sup>2+</sup>, and Hg<sup>2+</sup>. This quenched the NH<sub>2</sub>-MIL-53-M fluorescence and allowed to significantly increase the selectivity and sensitivity for detection of In<sup>3+</sup>, Cu<sup>2+</sup>, and Hg<sup>2+</sup>. The fluorescence quenching constant (<i>K</i><sub>sv</sub>) values were 2.23 × 10<sup>5</sup>, 1.00 × 10<sup>5</sup>, and 2.74 × 10<sup>4</sup> M<sup>-1</sup>, while the limit of detection (LODs) values were 0.06, 0.14, and 0.53 μM, for In<sup>3+</sup>, Cu<sup>2+</sup>, and Hg<sup>2+</sup>, respectively. The concentrations of In<sup>3+</sup>, Cu<sup>2+</sup>, and Hg<sup>2+</sup> in real environmental samples could be determined by addition of appropriate masking agents, and the recoveries were within the range of 94-110%. This study not only supplied a strategy for constructing a highly sensitive and selective fluorescent probe but also established a platform for simultaneous detection of multiple heavy metal ions in water.

ACS Applied Materials & InterfacesVol. 16(45)
Anhui Jianzhu University (CN), Anhui Special Equipment Inspection Institute (CN), Monash University (AU), Southeast University (CN)
National Natural Science Foundation of China, Natural Science Foundation of Anhui Province, Anhui Provincial Key Research and Development Plan
Clean water and sanitation
Openalex Percentile: Top 8%
Mercury impact and mitigation studies
3.15
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.