Force analysis and improvement of main transformer bushing terminal structure

Abstract After investigation, it was found that due to natural environmental conditions such as rain and snow temperature, equipment such as down conductor above the terminals, and natural swings of wires, the terminal blocks of the down conductor bushing on the high voltage side of the main transformer of a 500kV substation will deteriorate and deform. Following the force analysis and experiment on the down conductor bushing terminal block on the high voltage side of the main transformer, it is found that the weak structure of the bushing terminal block lies in the vertical orientation of the terminal and the connection point of the transverse structure, and its horizontal external force limit value is 1.91KN. In this paper, it was finally decided to improve the terminal structure by erecting diagonal supports between the vertical and transverse structures of the terminals. The improved terminal block can be subjected to an external force of 5KN horizontally, and the terminal shape is within the safe range. It can ensure the safety and stability of the main transformer bushing terminal block.

Authors

Institutions

Publication Details

Journal
Journal of Physics Conference Series
Published
2024-11-01
DOI
https://doi.org/10.1088/1742-6596/2876/1/012017
Primary Topic
Power Systems and Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Force analysis and improvement of main transformer bushing terminal structure

Kai Shi, Pei Hao, Yuping Wang, Dayong Wang et al.
Journal of Physics Conference Series
Power Systems and Technologies
article

Force analysis and improvement of main transformer bushing terminal structure

Kai Shi, Pei Hao, Yuping Wang, Dayong Wang, Hui Zhong, Haiyang Yu, R.-Y. Duan
article en

Abstract

Abstract After investigation, it was found that due to natural environmental conditions such as rain and snow temperature, equipment such as down conductor above the terminals, and natural swings of wires, the terminal blocks of the down conductor bushing on the high voltage side of the main transformer of a 500kV substation will deteriorate and deform. Following the force analysis and experiment on the down conductor bushing terminal block on the high voltage side of the main transformer, it is found that the weak structure of the bushing terminal block lies in the vertical orientation of the terminal and the connection point of the transverse structure, and its horizontal external force limit value is 1.91KN. In this paper, it was finally decided to improve the terminal structure by erecting diagonal supports between the vertical and transverse structures of the terminals. The improved terminal block can be subjected to an external force of 5KN horizontally, and the terminal shape is within the safe range. It can ensure the safety and stability of the main transformer bushing terminal block.

Journal of Physics Conference SeriesVol. 2876(1)
State Grid Corporation of China (China) (CN)
Life in Land
Openalex Percentile: Top 83%
Power Systems and Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Force analysis and improvement of main transformer bushing terminal structure — Kai Shi, Pei Hao, et al. · Journal of Physics Conference Series (2024) | TGRS Research Map | TGRS