A study on the reduction of high-temperature in the high-pressure piping system of civil aircraft

Abstract For the study of the bleed air flow process in high-pressure pipelines, theoretical analysis and numerical simulation were used to investigate the temperature drop problem in the pipelines. The effect of bleed air and ambient temperatures on the performance of temperature drop in high-pressure pipelines was discussed in detail. The performance of pipeline insulation before and after applying the insulation layer was also discussed. The results show that the higher bleed air temperature and lower ambient temperature obviously cause a greater drop in the bleed air temperature drop. The entrance section of the pipeline is approximately five times the l/d range. Applying the insulation layer can effectively reduce the drop in pipeline temperature. Generally, the air insulation layer can reduce the temperature drop of high-pressure pipeline gas by 25%. If further reduction is required, the vacuum insulation layer can be applied.

Authors

Institutions

Publication Details

Journal
Journal of Physics Conference Series
Published
2024-11-01
DOI
https://doi.org/10.1088/1742-6596/2876/1/012003
Primary Topic
Engineering Applied Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A study on the reduction of high-temperature in the high-pressure piping system of civil aircraft

Li Xuan, J. Liu, Li Jiang
Journal of Physics Conference Series
Engineering Applied Research
article

A study on the reduction of high-temperature in the high-pressure piping system of civil aircraft

Li Xuan, J. Liu, Li Jiang
article en

Abstract

Abstract For the study of the bleed air flow process in high-pressure pipelines, theoretical analysis and numerical simulation were used to investigate the temperature drop problem in the pipelines. The effect of bleed air and ambient temperatures on the performance of temperature drop in high-pressure pipelines was discussed in detail. The performance of pipeline insulation before and after applying the insulation layer was also discussed. The results show that the higher bleed air temperature and lower ambient temperature obviously cause a greater drop in the bleed air temperature drop. The entrance section of the pipeline is approximately five times the l/d range. Applying the insulation layer can effectively reduce the drop in pipeline temperature. Generally, the air insulation layer can reduce the temperature drop of high-pressure pipeline gas by 25%. If further reduction is required, the vacuum insulation layer can be applied.

Journal of Physics Conference SeriesVol. 2876(1)
Commercial Aircraft Corporation of China (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 78%
Engineering Applied Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.