Single-exposure beam quality analysis via lens-free coherent amplitude modulation imaging

A single-exposure method for complex amplitude reconstruction in beam quality analysis is proposed, utilizing lens-free coherent amplitude modulation imaging (LF-CAMI). This approach leverages a partially saturated diffraction pattern to reconstruct the complex amplitude of a measured laser beam. The corresponding intensity images near the beam waist along the axial direction are determined directly via the Fresnel diffraction formula. Spatial beam parameters, including the beam quality factor M<sup>2</sup>, are then calculated following the ISO 11146-1 standard. The feasibility of the proposed method is validated through theoretical analysis and experiments, targeting both static and dynamic laser beams. Experimental results demonstrate that this method yields results consistent with those obtained using commercial beam quality analysis instruments while reducing the total measurement time by approximately 80%. The proposed method is compact, cost-effective, and immune to aberrations and offers a fast and accurate measurement process, making it particularly suitable for beam quality analysis in various laser systems, especially pulsed laser systems.

Authors

Institutions

Publication Details

Journal
Optics Letters
Published
2024-11-05
DOI
https://doi.org/10.1364/ol.541211
Primary Topic
Advanced X-ray Imaging Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Single-exposure beam quality analysis via lens-free coherent amplitude modulation imaging

Zhilong Jiang, Suhas P. Veetil, Cheng Liu, Jianqiang Zhu et al.
Optics Letters
Advanced X-ray Imaging Techniques
article

Single-exposure beam quality analysis via lens-free coherent amplitude modulation imaging

Zhilong Jiang, Suhas P. Veetil, Cheng Liu, Jianqiang Zhu, Chunyu Zou
article en

Abstract

A single-exposure method for complex amplitude reconstruction in beam quality analysis is proposed, utilizing lens-free coherent amplitude modulation imaging (LF-CAMI). This approach leverages a partially saturated diffraction pattern to reconstruct the complex amplitude of a measured laser beam. The corresponding intensity images near the beam waist along the axial direction are determined directly via the Fresnel diffraction formula. Spatial beam parameters, including the beam quality factor M<sup>2</sup>, are then calculated following the ISO 11146-1 standard. The feasibility of the proposed method is validated through theoretical analysis and experiments, targeting both static and dynamic laser beams. Experimental results demonstrate that this method yields results consistent with those obtained using commercial beam quality analysis instruments while reducing the total measurement time by approximately 80%. The proposed method is compact, cost-effective, and immune to aberrations and offers a fast and accurate measurement process, making it particularly suitable for beam quality analysis in various laser systems, especially pulsed laser systems.

Optics LettersVol. 49(24)
Higher Colleges of Technology (AE), Chinese Academy of Sciences (CN)
Affordable and clean energy
Openalex Percentile: Top 72%
Advanced X-ray Imaging Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Single-exposure beam quality analysis via lens-free coherent amplitude modulation imaging — Zhilong Jiang, Suhas P. Veetil, et al. · Optics Letters (2024) | TGRS Research Map | TGRS