Embosphere Size Selection and Dilution Rate in Preoperative Tumor Embolization of the External Carotid Artery System Using a Small-diameter Catheter

The widespread adoption of preoperative embolization in highly vascularized brain tumors often involves the frequent use of Embosphere (Merit Medical Systems, South Jordan, Utah, USA). Nevertheless, inconsistency in size selection and dilution rates across different institutions requires comprehensive examination. This study explored the appropriate size and dilution rate of Embosphere microspheres. To assess catheter occlusion and Embosphere breakage, various dilutions (4-, 10-, 20-, 30-, and 60-fold) of Embosphere 300-500 and 500-700 μm were injected into the catheter in vitro. Results indicated that 20-fold or higher dilutions of Embosphere 300-500 μm and 30-fold or higher dilutions of Embosphere 500-700 μm showed no occlusion of the Excelsior SL-10 microcatheter (Stryker, Fremont, CA, USA) or Embosphere breakage. For embolization, to reduce the risk of Excelsior SL-10 occlusion further, a 30-fold dilution of Embosphere 300-500 μm and a 60-fold dilution of Embosphere 500-700 μm were employed. For 195 blood vessels in 107 patients (84 with meningioma and 23 with schwannoma), embolization was carried out using a 30-fold dilution of Embosphere 300-500 μm when the provocative test was negative and a 60-fold dilution of Embosphere 500-700 μm when the test was positive or when there was a risk of migration into neurotrophic vessels. Contrast-enhanced magnetic resonance imaging after embolization revealed a reduced enhancement effect in 69.1% of cases. Embolization using a 30-fold dilution of Embosphere 300-500 μm and a 60-fold dilution of Embosphere 500-700 μm with an Excelsior SL-10 catheter is safe and satisfactory, which minimizes microcatheter occlusion.

Authors

Institutions

Publication Details

Journal
Neurologia medico-chirurgica
Published
2024-11-05
DOI
https://doi.org/10.2176/jns-nmc.2024-0059
Citations
2
Primary Topic
Cerebrovascular and Carotid Artery Diseases
Type
article
Field-Weighted Citation Impact
0.84
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Embosphere Size Selection and Dilution Rate in Preoperative Tumor Embolization of the External Carotid Artery System Using a Small-diameter Catheter

Hirofumi Okada, Takao Hashimoto, Kyosuke Matsunaga, Muneaki Kikuno et al.
2 citations
Neurologia medico-chirurgica
Cerebrovascular and Carotid Artery Diseases
0.84
article

Embosphere Size Selection and Dilution Rate in Preoperative Tumor Embolization of the External Carotid Artery System Using a Small-diameter Catheter

Hirofumi Okada, Takao Hashimoto, Kyosuke Matsunaga, Muneaki Kikuno, Yusuke Arai, Michihiro Kohno, Hiroki Sakamoto
article en
2 citations

Abstract

The widespread adoption of preoperative embolization in highly vascularized brain tumors often involves the frequent use of Embosphere (Merit Medical Systems, South Jordan, Utah, USA). Nevertheless, inconsistency in size selection and dilution rates across different institutions requires comprehensive examination. This study explored the appropriate size and dilution rate of Embosphere microspheres. To assess catheter occlusion and Embosphere breakage, various dilutions (4-, 10-, 20-, 30-, and 60-fold) of Embosphere 300-500 and 500-700 μm were injected into the catheter in vitro. Results indicated that 20-fold or higher dilutions of Embosphere 300-500 μm and 30-fold or higher dilutions of Embosphere 500-700 μm showed no occlusion of the Excelsior SL-10 microcatheter (Stryker, Fremont, CA, USA) or Embosphere breakage. For embolization, to reduce the risk of Excelsior SL-10 occlusion further, a 30-fold dilution of Embosphere 300-500 μm and a 60-fold dilution of Embosphere 500-700 μm were employed. For 195 blood vessels in 107 patients (84 with meningioma and 23 with schwannoma), embolization was carried out using a 30-fold dilution of Embosphere 300-500 μm when the provocative test was negative and a 60-fold dilution of Embosphere 500-700 μm when the test was positive or when there was a risk of migration into neurotrophic vessels. Contrast-enhanced magnetic resonance imaging after embolization revealed a reduced enhancement effect in 69.1% of cases. Embolization using a 30-fold dilution of Embosphere 300-500 μm and a 60-fold dilution of Embosphere 500-700 μm with an Excelsior SL-10 catheter is safe and satisfactory, which minimizes microcatheter occlusion.

Neurologia medico-chirurgicaVol. 65(1)
Tokyo Medical University (JP)
Openalex Percentile: Top 23%
Cerebrovascular and Carotid Artery Diseases
0.84
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.