Biaxial eccentric behavior of improved multi-cell T-shaped concrete-filled steel tubes

The special-shaped concrete-filled steel tube (CFST) structure has attracted considerable scholarly interest in recent years. However, limited attention has been given to research on multi-cell T-shaped CFST (MT-CFST) column, resulting in a lack of uniformity in calculation methods. This paper presents an improved MT-CFST column composed of three rectangular steel tubes, a steel plate, and concrete. This design ensures that welds avoid cold bending zones in steel tubes, thereby enhancing quality of welds. In practical engineering applications , columns often experience biaxial eccentric loads . A biaxial eccentric compression test was conducted on fifteen MT-CFST specimens. This study investigated the influence of eccentricity, eccentric angle, and web height on performance of MT-CFST column. The experimental results revealed a similar failure mode among specimens: prior to peak load, minor bending deformation was observed. For specimens T56.6–60-45° and T40–90-180°, the smaller width-to-thickness ratio of steel plates on compressed side prevented local buckling. For other specimens, slight local buckling on compressed side near mid-span section was observed. After peak load, local buckling progressively intensified, primarily due to substantial bending deformation. The failure of specimens was attributed to local buckling and overall bending deformation. For eccentricity greater than 20 mm, the bearing capacity and elastic-plastic stiffness of specimens exhibited an increasing trend followed by a decreasing trend with the increase in eccentric angle at the same eccentricity, with the peaks occurring at around 90°. Specimens with the compressed side located at flange demonstrated higher bearing capacity and elastic-plastic stiffness. Additionally, FE models have been established to simulate the bidirectional eccentric behavior. A simplified method for calculating flexural capacity was developed, grounded in stress analysis of section at ultimate conditions. In accordance with ANSI/AISC 360, a method was established for predicting uniaxial eccentric capacity. By conducting a parametric analysis of M x / M ux,n - M y / M uy,n curves, a simplified method for determining M x / M ux,n - M y / M uy,n curves was proposed, with calculation results in good agreement with FE results. • Fifteen multi-cell T-shaped concrete-filled steel tubes were tested under biaxial eccentric compression. • Effects of eccentricity, eccentric angle, and web height on the performance of specimens were investigated. • The flexural capacity calculation method was proposed. • A simplified calculation method was presented to predict uniaxial eccentric capacity. • A simplified method for determining biaxial eccentric compression bearing capacity was proposed.

Authors

Institutions

Publication Details

Journal
Journal of Constructional Steel Research
Published
2024-11-05
DOI
https://doi.org/10.1016/j.jcsr.2024.109131
Citations
1
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.26

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biaxial eccentric behavior of improved multi-cell T-shaped concrete-filled steel tubes

Rui Cheng, Meilan Gong, Yu Wang, Jichun Liu et al.
1 citations
Journal of Constructional Steel Research
Structural Load-Bearing Analysis
0.26
article

Biaxial eccentric behavior of improved multi-cell T-shaped concrete-filled steel tubes

Rui Cheng, Meilan Gong, Yu Wang, Jichun Liu, Chao Hu
article en
1 citations

Abstract

The special-shaped concrete-filled steel tube (CFST) structure has attracted considerable scholarly interest in recent years. However, limited attention has been given to research on multi-cell T-shaped CFST (MT-CFST) column, resulting in a lack of uniformity in calculation methods. This paper presents an improved MT-CFST column composed of three rectangular steel tubes, a steel plate, and concrete. This design ensures that welds avoid cold bending zones in steel tubes, thereby enhancing quality of welds. In practical engineering applications , columns often experience biaxial eccentric loads . A biaxial eccentric compression test was conducted on fifteen MT-CFST specimens. This study investigated the influence of eccentricity, eccentric angle, and web height on performance of MT-CFST column. The experimental results revealed a similar failure mode among specimens: prior to peak load, minor bending deformation was observed. For specimens T56.6–60-45° and T40–90-180°, the smaller width-to-thickness ratio of steel plates on compressed side prevented local buckling. For other specimens, slight local buckling on compressed side near mid-span section was observed. After peak load, local buckling progressively intensified, primarily due to substantial bending deformation. The failure of specimens was attributed to local buckling and overall bending deformation. For eccentricity greater than 20 mm, the bearing capacity and elastic-plastic stiffness of specimens exhibited an increasing trend followed by a decreasing trend with the increase in eccentric angle at the same eccentricity, with the peaks occurring at around 90°. Specimens with the compressed side located at flange demonstrated higher bearing capacity and elastic-plastic stiffness. Additionally, FE models have been established to simulate the bidirectional eccentric behavior. A simplified method for calculating flexural capacity was developed, grounded in stress analysis of section at ultimate conditions. In accordance with ANSI/AISC 360, a method was established for predicting uniaxial eccentric capacity. By conducting a parametric analysis of M x / M ux,n - M y / M uy,n curves, a simplified method for determining M x / M ux,n - M y / M uy,n curves was proposed, with calculation results in good agreement with FE results. • Fifteen multi-cell T-shaped concrete-filled steel tubes were tested under biaxial eccentric compression. • Effects of eccentricity, eccentric angle, and web height on the performance of specimens were investigated. • The flexural capacity calculation method was proposed. • A simplified calculation method was presented to predict uniaxial eccentric capacity. • A simplified method for determining biaxial eccentric compression bearing capacity was proposed.

Journal of Constructional Steel ResearchVol. 224
Chongqing University (CN), Shenzhen General Institute of Architectural Design and Research (China) (CN), Guangzhou Design Institute (CN)
National Natural Science Foundation of China
Sustainable cities and communities
Openalex Percentile: Top 43%
Structural Load-Bearing Analysis
0.26
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.