Evaluating inverse modeling methods for measurement and verification of chiller energy efficiency measures

A commonly budget and time constrained yet crucial measurement and verification process for chiller energy efficiency measures often requires rarely trended chiller performance data for the pre-retrofit or post-retrofit chiller necessitating chiller modeling for year-round performance prediction. This study evaluates chiller inverse modeling methods for measurement and verification applications. Variable speed drive-controlled centrifugal chillers operating in a hot and humid climate are used as case studies. Two scenarios are explored: one where full-range metered chiller data are available and another with limited data that requires a short-term metering process. The biquadratic black-box and Gordon-Ng with a variable entropy term models perform exceptionally well when full-range chiller performance data is available, displaying a coefficient of variation of approximately 5 % for both training and test datasets . However, in situations that use short-term metered data not covering the full range, the fundamental and Foliaco reformulated Gordon-Ng models outperform other models. These models show minimal degradation in average statistical performance when trained with one-month metering data instead of four-month data, indicating their potential to capture the year-round chiller performance variation with short-term metered data. Furthermore, the optimal metering period for an accurate modeling process is identified as one containing data from at least one shoulder month like April, May, or October for a hot and humid climate. These findings provide valuable guidance for practitioners involved in chiller efficiency measure assessments, emphasizing the significance of proper model selection and an appropriate metering period for a reliable measurement and verification process. • M&V of chiller energy efficiency measures requires rarely available year-round data. • The biquadratic model performs best when trained with full-range chiller data. • A method to assess the performance of chiller inverse models for M&V is developed. • The Gordon-Ng model performs best when trained with shorter metering periods' data. • An optimum metering period should contain data from a shoulder season month.

Authors

Institutions

Publication Details

Journal
Applied Energy
Published
2024-11-05
DOI
https://doi.org/10.1016/j.apenergy.2024.124805
Citations
1
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.27
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluating inverse modeling methods for measurement and verification of chiller energy efficiency measures

Juan-Carlos Baltazar, D. E. Claridge, Martin Ssembatya
1 citations
Applied Energy
Building Energy and Comfort Optimization
0.27
article

Evaluating inverse modeling methods for measurement and verification of chiller energy efficiency measures

Juan-Carlos Baltazar, D. E. Claridge, Martin Ssembatya
article en
1 citations

Abstract

A commonly budget and time constrained yet crucial measurement and verification process for chiller energy efficiency measures often requires rarely trended chiller performance data for the pre-retrofit or post-retrofit chiller necessitating chiller modeling for year-round performance prediction. This study evaluates chiller inverse modeling methods for measurement and verification applications. Variable speed drive-controlled centrifugal chillers operating in a hot and humid climate are used as case studies. Two scenarios are explored: one where full-range metered chiller data are available and another with limited data that requires a short-term metering process. The biquadratic black-box and Gordon-Ng with a variable entropy term models perform exceptionally well when full-range chiller performance data is available, displaying a coefficient of variation of approximately 5 % for both training and test datasets . However, in situations that use short-term metered data not covering the full range, the fundamental and Foliaco reformulated Gordon-Ng models outperform other models. These models show minimal degradation in average statistical performance when trained with one-month metering data instead of four-month data, indicating their potential to capture the year-round chiller performance variation with short-term metered data. Furthermore, the optimal metering period for an accurate modeling process is identified as one containing data from at least one shoulder month like April, May, or October for a hot and humid climate. These findings provide valuable guidance for practitioners involved in chiller efficiency measure assessments, emphasizing the significance of proper model selection and an appropriate metering period for a reliable measurement and verification process. • M&V of chiller energy efficiency measures requires rarely available year-round data. • The biquadratic model performs best when trained with full-range chiller data. • A method to assess the performance of chiller inverse models for M&V is developed. • The Gordon-Ng model performs best when trained with shorter metering periods' data. • An optimum metering period should contain data from a shoulder season month.

Applied EnergyVol. 378
Makerere University (UG), Texas A&M University (US)
Affordable and clean energy
Openalex Percentile: Top 42%
Building Energy and Comfort Optimization
0.27
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.