Assessment of arteriosclerosis based on lognormal fitting

<i>Objective</i>. Pulse pressure waves contain information about human physiology. There is a need for a simple, accurate way to know cardiovascular health in the clinic, so as to realize the implementation of convenient and effective early health monitoring for patients with arteriosclerosis.<i>Approach</i>. This study proposes an arteriosclerosis assessment method based on fitting a lognormal function, along with improving a conventional electronic sphygmomanometer. During the deflation phase of blood pressure measurement, the cuff pressure was kept constant (40 mmHg) and an additional 10 s of pulse signal was acquired. To derive the pulse pressure waveforms for a single cycle, the acquired pulse data of 101 cases were preprocessed in this study, including filtering for noise removal, onset point identification, removal of baseline drift, and normalization. In this study, an improved pulse resolution algorithm is proposed for the multimodal problem of the pulse wave, combining waveform matching and threshold setting, and finally obtaining the resolution parameters of the lognormal function with an average error less than 1.5%.<i>Main results</i>. According to the correlation analysis, the resolved parameters<i>A</i><sub>1</sub>,<i>W</i><sub>2</sub>,<i>C</i><sub>2</sub>,<i>W</i><sub>3</sub>, and<i>C</i><sub>3</sub>were significantly correlated with brachial-ankle Pulse Wave Velocity, and the absolute correlation range in 0.17-0.53, which can be used as a reference index for arteriosclerosis. An arteriosclerosis assessment model was constructed based on the support vector mechanism, and the prediction accuracy was 91.1%.<i>Significance</i>. This study provides a new solution idea for the arteriosclerosis assessment method as well as the pulse resolution algorithm, which has a greater reference value.

Authors

Institutions

Publication Details

Journal
Physiological Measurement
Published
2024-11-01
DOI
https://doi.org/10.1088/1361-6579/ad8f29
Primary Topic
Cardiovascular Health and Disease Prevention
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of arteriosclerosis based on lognormal fitting

Ziqi Zhang, Haolin Tang, Chengyu Liu, Yumin Li et al.
Physiological Measurement
Cardiovascular Health and Disease Prevention
article

Assessment of arteriosclerosis based on lognormal fitting

Ziqi Zhang, Haolin Tang, Chengyu Liu, Yumin Li, Jianqing Li, T. Xiang, Lulu Zhao
article en

Abstract

<i>Objective</i>. Pulse pressure waves contain information about human physiology. There is a need for a simple, accurate way to know cardiovascular health in the clinic, so as to realize the implementation of convenient and effective early health monitoring for patients with arteriosclerosis.<i>Approach</i>. This study proposes an arteriosclerosis assessment method based on fitting a lognormal function, along with improving a conventional electronic sphygmomanometer. During the deflation phase of blood pressure measurement, the cuff pressure was kept constant (40 mmHg) and an additional 10 s of pulse signal was acquired. To derive the pulse pressure waveforms for a single cycle, the acquired pulse data of 101 cases were preprocessed in this study, including filtering for noise removal, onset point identification, removal of baseline drift, and normalization. In this study, an improved pulse resolution algorithm is proposed for the multimodal problem of the pulse wave, combining waveform matching and threshold setting, and finally obtaining the resolution parameters of the lognormal function with an average error less than 1.5%.<i>Main results</i>. According to the correlation analysis, the resolved parameters<i>A</i><sub>1</sub>,<i>W</i><sub>2</sub>,<i>C</i><sub>2</sub>,<i>W</i><sub>3</sub>, and<i>C</i><sub>3</sub>were significantly correlated with brachial-ankle Pulse Wave Velocity, and the absolute correlation range in 0.17-0.53, which can be used as a reference index for arteriosclerosis. An arteriosclerosis assessment model was constructed based on the support vector mechanism, and the prediction accuracy was 91.1%.<i>Significance</i>. This study provides a new solution idea for the arteriosclerosis assessment method as well as the pulse resolution algorithm, which has a greater reference value.

Physiological MeasurementVol. 45(11)
Nantong University (CN), Southeast University (BD), Nantong Science and Technology Bureau (CN), Southeast University (CN)
National Natural Science Foundation of China
Good health and well-being
Openalex Percentile: Top 64%
Cardiovascular Health and Disease Prevention
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.