External Validation of an Electronic Health Record–Based Diagnostic Model for Histological Acute Tubulointerstitial Nephritis

Key Points Individual noninvasive diagnostic tests lack accuracy for diagnosing histological acute tubulointerstitial nephritis. A validated diagnostic model combining four clinical tests accurately predicted acute tubulointerstitial nephritis on biopsy in two separate populations. Background Accurate diagnosis of acute tubulointerstitial nephritis (AIN) often requires a kidney biopsy. We previously developed a diagnostic statistical model for predicting biopsy-confirmed AIN by combining four laboratory tests after evaluating over 150 potential predictors from the electronic health record. In this study, we validate this diagnostic model in two biopsy-based cohorts at Johns Hopkins Hospital (JHH) and Yale University, which were geographically and temporally distinct from the development cohort, respectively. Methods We analyzed patients who underwent kidney biopsy at JHH and Yale University (2019–2023). We assessed discrimination (area under receiver-operating characteristics curve [AUC]) and calibration using previously derived model coefficients and recalibrated the model using an intercept correction factor that accounted for differences in baseline prevalence of AIN between development and validation cohorts. Results We included 1982 participants: 1454 at JHH and 528 at Yale. JHH (5%) and Yale (17%) had lower proportions of biopsies with AIN than the development set (23%). The AUC was 0.73 (95% confidence interval [CI], 0.66 to 0.79) at JHH and 0.73 (95% CI, 0.67 to 0.78) at Yale, similar to the development set (0.73 [95% CI, 0.64 to 0.81]). Calibration was imperfect in validation cohorts, particularly at JHH, but improved with the application of an intercept correction factor. The model increased AUC of clinicians’ prebiopsy suspicion for AIN by 0.10 to 0.77 (95% CI, 0.71 to 0.82). Conclusions An AIN diagnostic model retained discrimination in two validation cohorts but needed recalibration to account for local AIN prevalence. The model improved clinicians’ ability to predict AIN.

Authors

Institutions

Publication Details

Journal
Journal of the American Society of Nephrology
Published
2024-11-05
DOI
https://doi.org/10.1681/asn.0000000556
Citations
3
Primary Topic
Nephrotoxicity and Medicinal Plants
Type
article
Field-Weighted Citation Impact
1.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

External Validation of an Electronic Health Record–Based Diagnostic Model for Histological Acute Tubulointerstitial Nephritis

F. Perry Wilson, Heather Thiessen‐Philbrook, Kimber Shelton, Melissa Shaw et al.
3 citations
Journal of the American Society of Nephrology
Nephrotoxicity and Medicinal Plants
1.21
article

External Validation of an Electronic Health Record–Based Diagnostic Model for Histological Acute Tubulointerstitial Nephritis

F. Perry Wilson, Heather Thiessen‐Philbrook, Kimber Shelton, Melissa Shaw, Chirag R. Parikh, Abinet M. Aklilu, Dennis G. Moledina, Amrita Makhijani, Michael Simonov, Steven Menez, Bashar Kadhim, Kyle O’Connor, David Hu, Jack Bitzel, Yu Yamamoto, Candice Kent
article en
3 citations

Abstract

Key Points Individual noninvasive diagnostic tests lack accuracy for diagnosing histological acute tubulointerstitial nephritis. A validated diagnostic model combining four clinical tests accurately predicted acute tubulointerstitial nephritis on biopsy in two separate populations. Background Accurate diagnosis of acute tubulointerstitial nephritis (AIN) often requires a kidney biopsy. We previously developed a diagnostic statistical model for predicting biopsy-confirmed AIN by combining four laboratory tests after evaluating over 150 potential predictors from the electronic health record. In this study, we validate this diagnostic model in two biopsy-based cohorts at Johns Hopkins Hospital (JHH) and Yale University, which were geographically and temporally distinct from the development cohort, respectively. Methods We analyzed patients who underwent kidney biopsy at JHH and Yale University (2019–2023). We assessed discrimination (area under receiver-operating characteristics curve [AUC]) and calibration using previously derived model coefficients and recalibrated the model using an intercept correction factor that accounted for differences in baseline prevalence of AIN between development and validation cohorts. Results We included 1982 participants: 1454 at JHH and 528 at Yale. JHH (5%) and Yale (17%) had lower proportions of biopsies with AIN than the development set (23%). The AUC was 0.73 (95% confidence interval [CI], 0.66 to 0.79) at JHH and 0.73 (95% CI, 0.67 to 0.78) at Yale, similar to the development set (0.73 [95% CI, 0.64 to 0.81]). Calibration was imperfect in validation cohorts, particularly at JHH, but improved with the application of an intercept correction factor. The model increased AUC of clinicians’ prebiopsy suspicion for AIN by 0.10 to 0.77 (95% CI, 0.71 to 0.82). Conclusions An AIN diagnostic model retained discrimination in two validation cohorts but needed recalibration to account for local AIN prevalence. The model improved clinicians’ ability to predict AIN.

Journal of the American Society of NephrologyVol. 36(5)
Johns Hopkins University (US), Yale University (US)
Peace, Justice and strong institutions
Openalex Percentile: Top 19%
Nephrotoxicity and Medicinal Plants
1.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.