Hazard, risk, reliability assessment and improvement of Darlington Tritium Removal Facility (DTRF) cryogenic refrigeration system

<ns3:p>Tritium is a radioactive isotope of hydrogen, produced in heavy water, during CANDU reactor operations by neutron absorption. The tritium removal facility at Darlington (DTRF) is used to extract tritium from the heavy water on a continuous basis and concentrates it in preparation for immobilization and storage. There are several internal and external hazards associated with the operation of DTRF, such as fires, onsite transportation accidents, exposure to radioactive materials, explosion due to Hydrogen (H2) and the release of radioactive substances from the Tritium Immobilization System. This paper conducts a risk analysis for the DTRF Cryogenic Refrigeration System, associated with both Low and High Tritium Distillation columns. This study includes hazard identification, consequence analysis and risk estimation. Fault Tree and Event Tree Analysis conducted, system reliability, availability and human reliability was considered. Consequently, methods for risk reduction and integration with improvement to CRS design is discussed.</ns3:p>

Authors

Publication Details

Journal
Nuclear Science and Technology Open Research
Published
2024-11-05
DOI
https://doi.org/10.12688/nuclscitechnolopenres.17611.1
Primary Topic
Superconducting Materials and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Hazard, risk, reliability assessment and improvement of Darlington Tritium Removal Facility (DTRF) cryogenic refrigeration system

Lixuan Lu, Allan Ghaforian, Miral Baytekin
Nuclear Science and Technology Open Research
Superconducting Materials and Applications
article

Hazard, risk, reliability assessment and improvement of Darlington Tritium Removal Facility (DTRF) cryogenic refrigeration system

Lixuan Lu, Allan Ghaforian, Miral Baytekin
article en

Abstract

<ns3:p>Tritium is a radioactive isotope of hydrogen, produced in heavy water, during CANDU reactor operations by neutron absorption. The tritium removal facility at Darlington (DTRF) is used to extract tritium from the heavy water on a continuous basis and concentrates it in preparation for immobilization and storage. There are several internal and external hazards associated with the operation of DTRF, such as fires, onsite transportation accidents, exposure to radioactive materials, explosion due to Hydrogen (H2) and the release of radioactive substances from the Tritium Immobilization System. This paper conducts a risk analysis for the DTRF Cryogenic Refrigeration System, associated with both Low and High Tritium Distillation columns. This study includes hazard identification, consequence analysis and risk estimation. Fault Tree and Event Tree Analysis conducted, system reliability, availability and human reliability was considered. Consequently, methods for risk reduction and integration with improvement to CRS design is discussed.</ns3:p>

Nuclear Science and Technology Open ResearchVol. 2
Openalex Percentile: Top 82%
Superconducting Materials and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Hazard, risk, reliability assessment and improvement of Darlington Tritium Removal Facility (DTRF) cryogenic refrigeration system — Lixuan Lu, Allan Ghaforian, et al. · Nuclear Science and Technology Open Research (2024) | TGRS Research Map | TGRS