Feasibility of Backscattering Coefficient Evaluation of Soft Tissue Using High-Frequency Annular Array Probe

The objective of this work is to address the need for versatile and effective tissue characterization in abdominal ultrasound diagnosis using a simpler system. We evaluated the backscattering coefficient (BSC) of several tissue-mimicking phantoms utilizing three different ultrasonic probes: a single-element transducer, a linear array probe for clinical use, and a laboratory-made annular array probe. The single-element transducer, commonly used in developing fundamental BSC evaluation methods, served as a benchmark. The linear array probe provided a clinical comparison, while the annular array probe was tested for its potential in high-frequency and high-resolution ultrasonic observations. Our findings demonstrate that the annular array probe meets clinical demands by providing accurate BSC measurements, showcasing its capability for high-frequency and high-resolution imaging with a simpler, more versatile system.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2024-11-05
DOI
https://doi.org/10.3390/s24227118
Primary Topic
Ultrasound Imaging and Elastography
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Feasibility of Backscattering Coefficient Evaluation of Soft Tissue Using High-Frequency Annular Array Probe

Kenji Yoshida, Shinnosuke Hirata, Cameron Hoerig, Tadashi Yamaguchi et al.
Sensors
Ultrasound Imaging and Elastography
article

Feasibility of Backscattering Coefficient Evaluation of Soft Tissue Using High-Frequency Annular Array Probe

Kenji Yoshida, Shinnosuke Hirata, Cameron Hoerig, Tadashi Yamaguchi, Jihoon Choi, Jonathan Mamou, Jeffrey A. Ketterling
article en

Abstract

The objective of this work is to address the need for versatile and effective tissue characterization in abdominal ultrasound diagnosis using a simpler system. We evaluated the backscattering coefficient (BSC) of several tissue-mimicking phantoms utilizing three different ultrasonic probes: a single-element transducer, a linear array probe for clinical use, and a laboratory-made annular array probe. The single-element transducer, commonly used in developing fundamental BSC evaluation methods, served as a benchmark. The linear array probe provided a clinical comparison, while the annular array probe was tested for its potential in high-frequency and high-resolution ultrasonic observations. Our findings demonstrate that the annular array probe meets clinical demands by providing accurate BSC measurements, showcasing its capability for high-frequency and high-resolution imaging with a simpler, more versatile system.

SensorsVol. 24(22)
Chiba University (JP), Cornell University (US), Weill Cornell Medicine (US)
Chiba University, National Institutes of Health, Weill Cornell Medical College, Japan Society for the Promotion of Science
Industry, innovation and infrastructure
Openalex Percentile: Top 67%
Ultrasound Imaging and Elastography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Feasibility of Backscattering Coefficient Evaluation of Soft Tissue Using High-Frequency Annular Array Probe — Kenji Yoshida, Shinnosuke Hirata, et al. · Sensors (2024) | TGRS Research Map | TGRS