Full-Field Modal Analysis of a Tensegrity Column Using a Three-Dimensional Scanning Laser Doppler Vibrometer With a Mirror

Abstract Tensegrity structures become important components of various engineering structures due to their high stiffness, light weight, and deployable capability. Existing studies on their dynamic analyses mainly focus on responses of their nodal points while overlook deformations of their cable and strut members. This study proposes a non-contact approach for the experimental modal analysis of a tensegrity structure to identify its three-dimensional (3D) natural frequencies and full-field mode shapes, which include modes with deformations of its cable and strut members. A 3D scanning laser Doppler vibrometer is used with a mirror for extending its field of view to measure full-field vibration of a novel three-strut metal tensegrity column with free boundaries. Tensions and axial stiffnesses of its cable members are determined using natural frequencies of their transverse and longitudinal modes, respectively, to build its theoretical model for dynamic analysis and model validation purposes. Modal assurance criterion (MAC) values between experimental and theoretical mode shapes are used to identify their paired modes. Modal parameters of the first 15 elastic modes of the tensegrity column identified from the experiment, including those of the overall structure and its cable members, can be classified into five mode groups depending on their types. Modes paired between experimental and theoretical results have MAC values larger than 78%. Differences between natural frequencies of paired modes of the tensegrity column are less than 15%. The proposed non-contact 3D vibration measurement approach allows accurate estimation of 3D full-field modal parameters of the tensegrity column.

Authors

Institutions

Publication Details

Journal
Journal of vibration and acoustics
Published
2024-11-05
DOI
https://doi.org/10.1115/1.4067079
Citations
5
Primary Topic
Structural Analysis and Optimization
Type
article
Field-Weighted Citation Impact
1.30

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Full-Field Modal Analysis of a Tensegrity Column Using a Three-Dimensional Scanning Laser Doppler Vibrometer With a Mirror

Sichen Yuan, Ke Yuan, Weidong Zhu
5 citations
Journal of vibration and acoustics
Structural Analysis and Optimization
1.30
article

Full-Field Modal Analysis of a Tensegrity Column Using a Three-Dimensional Scanning Laser Doppler Vibrometer With a Mirror

Sichen Yuan, Ke Yuan, Weidong Zhu
article en
5 citations

Abstract

Abstract Tensegrity structures become important components of various engineering structures due to their high stiffness, light weight, and deployable capability. Existing studies on their dynamic analyses mainly focus on responses of their nodal points while overlook deformations of their cable and strut members. This study proposes a non-contact approach for the experimental modal analysis of a tensegrity structure to identify its three-dimensional (3D) natural frequencies and full-field mode shapes, which include modes with deformations of its cable and strut members. A 3D scanning laser Doppler vibrometer is used with a mirror for extending its field of view to measure full-field vibration of a novel three-strut metal tensegrity column with free boundaries. Tensions and axial stiffnesses of its cable members are determined using natural frequencies of their transverse and longitudinal modes, respectively, to build its theoretical model for dynamic analysis and model validation purposes. Modal assurance criterion (MAC) values between experimental and theoretical mode shapes are used to identify their paired modes. Modal parameters of the first 15 elastic modes of the tensegrity column identified from the experiment, including those of the overall structure and its cable members, can be classified into five mode groups depending on their types. Modes paired between experimental and theoretical results have MAC values larger than 78%. Differences between natural frequencies of paired modes of the tensegrity column are less than 15%. The proposed non-contact 3D vibration measurement approach allows accurate estimation of 3D full-field modal parameters of the tensegrity column.

Journal of vibration and acousticsVol. 146(6)
University of Alabama (US), University of Maryland, Baltimore County (US)
National Science Foundation
Openalex Percentile: Top 21%
Structural Analysis and Optimization
1.30
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Full-Field Modal Analysis of a Tensegrity Column Using a Three-Dimensional Scanning Laser Doppler Vibrometer With a Mirror — Sichen Yuan, Ke Yuan, et al. · Journal of vibration and acoustics (2024) | TGRS Research Map | TGRS