Cavity-enhanced Faraday rotation spectroscopy for interference-free measurement of OH radical at 2.8 μm

An instrument based on cavity-enhanced Faraday rotation spectroscopy (CE-FRS) operating at 2.8 μm has been developed for interference-free measurement of OH radicals in the laboratory. By off-axis coupling of a continuous-wave laser into a high finesse optical cavity, FRS signal is obtained from balanced detection of time-integrated light intensity leaking out of the cavity in the presence of magnetic field. Radio-frequency white noise (5–520 MHz) was injected into laser current which reduced intensity fluctuations in cavity transmission, thus improved the signal-to-noise ratio of the spectroscopic signal by a factor of 2. The setup provides a simple and robust spectroscopic instrument for in-situ and highly-selective detection of paramagnetic species. We demonstrated the instrument’s capabilities using OH radical with concentration in the range of 10 12 molecule.cm −3 , generated by microwave discharge of water vapor at low pressure. The CE-FRS instrument exhibited a limit of detection of ∼ 10 10 molecule.cm −3 in an integration time of 20 s, which is enhanced by a factor of 2.5 compared to cavity-enhanced wavelength modulation spectroscopy involving an off-axis integrated cavity output spectroscopy approach. A time-resolved FRS signal was recorded in a pulsed microwave discharge regime, giving a millisecond time resolution for the measurement of OH concentration profile. The developed instrument provides a potential analytical tool for the measurement of OH concentration for chemical kinetic study in reactor cells. • Demonstration of off-axis cavity-enhanced Faraday rotation spectroscopy (CE-FRS). • Balanced FRS detection of time-integrated cavity output. • Radio-frequency White noise injection to reduce laser intensity fluctuations. • Real-time interference-free in situ measurement of OH radicals using CE-FRS. • Capacity of monitoring OH concentration profile in millisecond time resolution.

Authors

Institutions

Publication Details

Journal
Sensors and Actuators B Chemical
Published
2024-11-05
DOI
https://doi.org/10.1016/j.snb.2024.136901
Citations
2
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
0.48

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cavity-enhanced Faraday rotation spectroscopy for interference-free measurement of OH radical at 2.8 μm

Nhut Minh Ngo, Fabrice Cazier, Cécile Cœur, Nicolas Houzel et al.
2 citations
Sensors and Actuators B Chemical
Spectroscopy and Laser Applications
0.48
article

Cavity-enhanced Faraday rotation spectroscopy for interference-free measurement of OH radical at 2.8 μm

Nhut Minh Ngo, Fabrice Cazier, Cécile Cœur, Nicolas Houzel, Dorothée Dewaële, Weidong Chen, Weixiong Zhao, Tong Nguyen-Ba
article en
2 citations

Abstract

An instrument based on cavity-enhanced Faraday rotation spectroscopy (CE-FRS) operating at 2.8 μm has been developed for interference-free measurement of OH radicals in the laboratory. By off-axis coupling of a continuous-wave laser into a high finesse optical cavity, FRS signal is obtained from balanced detection of time-integrated light intensity leaking out of the cavity in the presence of magnetic field. Radio-frequency white noise (5–520 MHz) was injected into laser current which reduced intensity fluctuations in cavity transmission, thus improved the signal-to-noise ratio of the spectroscopic signal by a factor of 2. The setup provides a simple and robust spectroscopic instrument for in-situ and highly-selective detection of paramagnetic species. We demonstrated the instrument’s capabilities using OH radical with concentration in the range of 10 12 molecule.cm −3 , generated by microwave discharge of water vapor at low pressure. The CE-FRS instrument exhibited a limit of detection of ∼ 10 10 molecule.cm −3 in an integration time of 20 s, which is enhanced by a factor of 2.5 compared to cavity-enhanced wavelength modulation spectroscopy involving an off-axis integrated cavity output spectroscopy approach. A time-resolved FRS signal was recorded in a pulsed microwave discharge regime, giving a millisecond time resolution for the measurement of OH concentration profile. The developed instrument provides a potential analytical tool for the measurement of OH concentration for chemical kinetic study in reactor cells. • Demonstration of off-axis cavity-enhanced Faraday rotation spectroscopy (CE-FRS). • Balanced FRS detection of time-integrated cavity output. • Radio-frequency White noise injection to reduce laser intensity fluctuations. • Real-time interference-free in situ measurement of OH radicals using CE-FRS. • Capacity of monitoring OH concentration profile in millisecond time resolution.

Sensors and Actuators B ChemicalVol. 424
Université du littoral côte d'opale (FR), Laboratoire de Physico-Chimie de l'Atmosphère (FR), Anhui Institute of Optics and Fine Mechanics (CN)
Agence Nationale de la Recherche, H2020 European Institute of Innovation and Technology
Affordable and clean energy
Openalex Percentile: Top 39%
Spectroscopy and Laser Applications
0.48
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.