Backup subscription scheme for differential protection using IEC61850-9-2 sampled values

Abstract In IEC-61850-based digital substations, the protection IED’s performance is dependent on merging unit’s vendor implementation, communication networks, and measurement circuit’s health conditions. As the process bus Sampled Value(SV) enables the availability of all sensor data on a communication network, this paper proposes a Backup Subscription scheme (BSS) for a transformer differential protection (87T, PDIF) function. BSS utilizes sensor data in digital substations to achieve a flexible protection scheme using a dynamic subscription feature. Thus, in case of failure of one sensor, differential protection would be maintained. The paper presents the implementation and verification of a prototyped scheme using a Hardware-in-the-loop simulation test bed. The main result is that BSS integration into differential protection ensures its dependability and security. Moreover, delay compensation and seamless switching feature increases the availability of differential protection.

Authors

Institutions

Publication Details

Journal
Energy Informatics
Published
2024-11-05
DOI
https://doi.org/10.1186/s42162-024-00409-0
Citations
2
Primary Topic
Smart Grid Security and Resilience
Type
article
Field-Weighted Citation Impact
0.66

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Backup subscription scheme for differential protection using IEC61850-9-2 sampled values

Irina Oļeiņikova, Mohammad Khalili Katoulaei, Bruce A. Mork, Hans Kristian Høidalen et al.
2 citations
Energy Informatics
Smart Grid Security and Resilience
0.66
article

Backup subscription scheme for differential protection using IEC61850-9-2 sampled values

Irina Oļeiņikova, Mohammad Khalili Katoulaei, Bruce A. Mork, Hans Kristian Høidalen, Aamir Rahmani
article en
2 citations

Abstract

Abstract In IEC-61850-based digital substations, the protection IED’s performance is dependent on merging unit’s vendor implementation, communication networks, and measurement circuit’s health conditions. As the process bus Sampled Value(SV) enables the availability of all sensor data on a communication network, this paper proposes a Backup Subscription scheme (BSS) for a transformer differential protection (87T, PDIF) function. BSS utilizes sensor data in digital substations to achieve a flexible protection scheme using a dynamic subscription feature. Thus, in case of failure of one sensor, differential protection would be maintained. The paper presents the implementation and verification of a prototyped scheme using a Hardware-in-the-loop simulation test bed. The main result is that BSS integration into differential protection ensures its dependability and security. Moreover, delay compensation and seamless switching feature increases the availability of differential protection.

Energy InformaticsVol. 7(1)
Michigan Technological University (US), Norwegian University of Science and Technology (NO)
Norges Forskningsråd
Openalex Percentile: Top 29%
Smart Grid Security and Resilience
0.66
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Backup subscription scheme for differential protection using IEC61850-9-2 sampled values — Irina Oļeiņikova, Mohammad Khalili Katoulaei, et al. · Energy Informatics (2024) | TGRS Research Map | TGRS