Accuracy of recent intraocular lens power calculation methods in post-myopic LASIK eyes

This retrospective study compared postoperative prediction errors of recent formulas using standard- or total keratometry (K or TK) for intraocular lens (IOL) power calculation in post-myopic LASIK patients. It included 56 eyes of 56 patients who underwent uncomplicated cataract surgery, with at least 1-month follow-up at Keio University Hospital in Tokyo or Hayashi Eye Hospital in Yokohama, Japan. Prediction errors, absolute errors, and percentage of eyes with prediction errors within ± 0.25 D, ± 0.50 D, and ± 1.00 D were calculated using nine formulas: Barrett True-K, Barrett True-K TK, Haigis-L, Haigis TK, Pearl-DGS, Hoffer QST, Hoffer QST PK, EVO K, and EVO PK. Statistical comparisons utilized Friedman test, Conover's all-pairs post-hoc, Cochran's Q, and McNemar post-hoc testing. Root-Mean-Square Error (RMSE) was compared with heteroscedastic testing. Barrett True-K TK had the lowest median predicted refractive error (-0.01). EVO PK had the smallest median absolute error (0.20). EVO PK had the highest percentage of eyes within ± 0.25 D of the predicted value (58.9%), significantly better than Haigis-L (p = 0.047). EVO PK had the lowest mean RMSE value (0.499). The EVO PK formula yielded the most accurate IOL power calculation in post-myopic LASIK eyes, with TK/PK values enhancing accuracy.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2024-11-03
DOI
https://doi.org/10.1038/s41598-024-78266-w
Citations
3
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
article
Field-Weighted Citation Impact
1.16
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy of recent intraocular lens power calculation methods in post-myopic LASIK eyes

Yasuyo Nishi, Hidemasa Torii, Miki Kamikawatoko Omoto, Erisa Yotsukura et al.
3 citations
Scientific Reports
Ophthalmology and Visual Impairment Studies
1.16
article

Accuracy of recent intraocular lens power calculation methods in post-myopic LASIK eyes

Yasuyo Nishi, Hidemasa Torii, Miki Kamikawatoko Omoto, Erisa Yotsukura, Masahiko Ayaki, Ken Hayashi, Sachiko Masui, Kate Gettinger, Kazuno Negishi
article en
3 citations

Abstract

This retrospective study compared postoperative prediction errors of recent formulas using standard- or total keratometry (K or TK) for intraocular lens (IOL) power calculation in post-myopic LASIK patients. It included 56 eyes of 56 patients who underwent uncomplicated cataract surgery, with at least 1-month follow-up at Keio University Hospital in Tokyo or Hayashi Eye Hospital in Yokohama, Japan. Prediction errors, absolute errors, and percentage of eyes with prediction errors within ± 0.25 D, ± 0.50 D, and ± 1.00 D were calculated using nine formulas: Barrett True-K, Barrett True-K TK, Haigis-L, Haigis TK, Pearl-DGS, Hoffer QST, Hoffer QST PK, EVO K, and EVO PK. Statistical comparisons utilized Friedman test, Conover's all-pairs post-hoc, Cochran's Q, and McNemar post-hoc testing. Root-Mean-Square Error (RMSE) was compared with heteroscedastic testing. Barrett True-K TK had the lowest median predicted refractive error (-0.01). EVO PK had the smallest median absolute error (0.20). EVO PK had the highest percentage of eyes within ± 0.25 D of the predicted value (58.9%), significantly better than Haigis-L (p = 0.047). EVO PK had the lowest mean RMSE value (0.499). The EVO PK formula yielded the most accurate IOL power calculation in post-myopic LASIK eyes, with TK/PK values enhancing accuracy.

Scientific ReportsVol. 14(1)
Keio University (JP), Hayashi Eye Hospital (JP)
Openalex Percentile: Top 19%
Ophthalmology and Visual Impairment Studies
1.16
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.