External validation of a quantitative model to guide patient selection for placement of an optional or permanent inferior vena ca va filter

Objectives: The objective of this study was to validate a previously published quantitative model that predicts the likelihood of an optional inferior vena cava filter (IVCF) being kept as a permanent device in a different patient population. Material and Methods: An institutional database of IVCF patients from 2016 to 2018 was reviewed. As in the published reference, if a retrieval was attempted, the IVCF was categorized as “removed;” if no attempt was performed, the filter was categorized as “kept permanent.” Patient parameters, such as age, sex, history of venous thromboembolism, presence of neurologic disease, presence of malignancy, as well as indications for IVCF placement were analyzed. The previously published formula was applied to analyze its ability to predict the likelihood of an optional IVCF being kept permanently in a new, external population. Results: A total of 270 patients were identified. Seventy-one filters were “removed” and 199 were “kept permanent.” Advanced age (odds ratio [OR] 1.05; 95% confidence interval [CI] 1.03–1.07) and presence of malignancy (OR 2.55; 95% CI 1.29–5.07) were the factors associated with the IVCF being “kept permanent” versus “removed.” None of the other parameters was statistically significant. The receiver operating characteristic curve yielded the area under the curve of 0.66, compared to the previously published value of 0.8. The sensitivity and specificity of the model were 64.3% and 62.0%, respectively. Conclusion: Advanced age and presence of malignancy were associated with optional IVCFs being kept as permanent devices. However, the previously published formula did not yield an accurate quantitative prediction in this external patient population.

Authors

Institutions

Publication Details

Journal
American Journal of Interventional Radiology
Published
2024-11-04
DOI
https://doi.org/10.25259/ajir_32_2024
Primary Topic
Venous Thromboembolism Diagnosis and Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

External validation of a quantitative model to guide patient selection for placement of an optional or permanent inferior vena ca va filter

Husameddin El Khudari, Aliaksei Salei, Eun Kyoo Song, Andrew J. Gunn et al.
American Journal of Interventional Radiology
Venous Thromboembolism Diagnosis and Management
article

External validation of a quantitative model to guide patient selection for placement of an optional or permanent inferior vena ca va filter

Husameddin El Khudari, Aliaksei Salei, Eun Kyoo Song, Andrew J. Gunn, Yufeng Li, Scott M. Brown
article en

Abstract

Objectives: The objective of this study was to validate a previously published quantitative model that predicts the likelihood of an optional inferior vena cava filter (IVCF) being kept as a permanent device in a different patient population. Material and Methods: An institutional database of IVCF patients from 2016 to 2018 was reviewed. As in the published reference, if a retrieval was attempted, the IVCF was categorized as “removed;” if no attempt was performed, the filter was categorized as “kept permanent.” Patient parameters, such as age, sex, history of venous thromboembolism, presence of neurologic disease, presence of malignancy, as well as indications for IVCF placement were analyzed. The previously published formula was applied to analyze its ability to predict the likelihood of an optional IVCF being kept permanently in a new, external population. Results: A total of 270 patients were identified. Seventy-one filters were “removed” and 199 were “kept permanent.” Advanced age (odds ratio [OR] 1.05; 95% confidence interval [CI] 1.03–1.07) and presence of malignancy (OR 2.55; 95% CI 1.29–5.07) were the factors associated with the IVCF being “kept permanent” versus “removed.” None of the other parameters was statistically significant. The receiver operating characteristic curve yielded the area under the curve of 0.66, compared to the previously published value of 0.8. The sensitivity and specificity of the model were 64.3% and 62.0%, respectively. Conclusion: Advanced age and presence of malignancy were associated with optional IVCFs being kept as permanent devices. However, the previously published formula did not yield an accurate quantitative prediction in this external patient population.

American Journal of Interventional RadiologyVol. 8
University of Alabama at Birmingham (US), Brookwood Baptist Health (US)
Openalex Percentile: Top 61%
Venous Thromboembolism Diagnosis and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.