Diagnostic performance of high and ultra-high-resolution photon counting CT for detection of coronary artery disease in patients evaluated for transcatheter aortic valve implantation

We assessed the diagnostic performance of both ultra-high-resolution (UHR) and high-resolution (HR) modes of photon-counting detector (PCD)-CT within the confines of standard pre-TAVI CT scans, as well as the performance of UHR mode adjusted specifically for coronary imaging, using quantitative coronary angiography (QCA) as the reference. We included 60 patients undergoing pre-TAVI planning CT scans. Patients were divided into 3 groups: 20 scanned in HR mode, 20 in UHR mode, and 20 in adjusted UHR mode, on a dual-source PCD-CT. The adjusted UHR mode employed a lower tube voltage (90 kV vs. 120 kV) and a higher image quality level (65 vs. 34) to enhance coronary artery visualization. Patients underwent invasive coronary angiography as part of clinical routine. CCTA and QCA were reviewed to assess CAD presence defined as stenosis ≥ 50% in proximal and middle coronary segments. We included 60 patients (mean age 79 ± 7 years; 39(65%) men). Mean heart rate during scanning was 72 ± 13 bpm. Median coronary calcium score was 973 [379-2007]. QCA identified significant CAD in 24 patients (40%): 9 patients scanned with HR mode, 10 patients with the UHR mode, and 5 patients with the UHR adjusted mode. Per-patient area under the curves were 0.57 for HR, 0.80 for UHR, and 0.80 for adjusted UHR, with no significant differences between the scan modes, and per-vessel the area under the curves were 0.73 for HR, 0.69 for UHR, and 0.87 for adjusted UHR, with significant differences between UHR and adjusted UHR (p = 0.04). UHR and adjusted UHR modes of dual source PCD-CT show potential for improved sensitivity and negative predictive value for detecting CAD in patients undergoing pre-TAVI scans, however, no statistically significant difference from HR mode was observed.

Authors

Institutions

Publication Details

Journal
The International Journal of Cardiovascular Imaging
Published
2024-11-04
DOI
https://doi.org/10.1007/s10554-024-03273-x
Citations
10
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
1.84
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Diagnostic performance of high and ultra-high-resolution photon counting CT for detection of coronary artery disease in patients evaluated for transcatheter aortic valve implantation

Marcel L. Dijkshoorn, Nicolas M. Van Mieghem, Ricardo P.J. Budde, Sarah Verhemel et al.
10 citations
The International Journal of Cardiovascular Imaging
Advanced X-ray and CT Imaging
1.84
article

Diagnostic performance of high and ultra-high-resolution photon counting CT for detection of coronary artery disease in patients evaluated for transcatheter aortic valve implantation

Marcel L. Dijkshoorn, Nicolas M. Van Mieghem, Ricardo P.J. Budde, Sarah Verhemel, Judith van der Bie, Simran P. Sharma, Alexander Hirsch, Joost Daemen
article en
10 citations

Abstract

We assessed the diagnostic performance of both ultra-high-resolution (UHR) and high-resolution (HR) modes of photon-counting detector (PCD)-CT within the confines of standard pre-TAVI CT scans, as well as the performance of UHR mode adjusted specifically for coronary imaging, using quantitative coronary angiography (QCA) as the reference. We included 60 patients undergoing pre-TAVI planning CT scans. Patients were divided into 3 groups: 20 scanned in HR mode, 20 in UHR mode, and 20 in adjusted UHR mode, on a dual-source PCD-CT. The adjusted UHR mode employed a lower tube voltage (90 kV vs. 120 kV) and a higher image quality level (65 vs. 34) to enhance coronary artery visualization. Patients underwent invasive coronary angiography as part of clinical routine. CCTA and QCA were reviewed to assess CAD presence defined as stenosis ≥ 50% in proximal and middle coronary segments. We included 60 patients (mean age 79 ± 7 years; 39(65%) men). Mean heart rate during scanning was 72 ± 13 bpm. Median coronary calcium score was 973 [379-2007]. QCA identified significant CAD in 24 patients (40%): 9 patients scanned with HR mode, 10 patients with the UHR mode, and 5 patients with the UHR adjusted mode. Per-patient area under the curves were 0.57 for HR, 0.80 for UHR, and 0.80 for adjusted UHR, with no significant differences between the scan modes, and per-vessel the area under the curves were 0.73 for HR, 0.69 for UHR, and 0.87 for adjusted UHR, with significant differences between UHR and adjusted UHR (p = 0.04). UHR and adjusted UHR modes of dual source PCD-CT show potential for improved sensitivity and negative predictive value for detecting CAD in patients undergoing pre-TAVI scans, however, no statistically significant difference from HR mode was observed.

The International Journal of Cardiovascular ImagingVol. 42(3)
Erasmus MC (NL), Erasmus MC Cancer Institute (NL), Erasmus University Rotterdam (NL)
Good health and well-being
Openalex Percentile: Top 15%
Advanced X-ray and CT Imaging
1.84
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.