Exploring Geometric Properties and Cycle Design in Packed Bed and Monolith Contactors Using Temperature-Vacuum Swing Adsorption Modeling for Direct Air Capture

This study presents a comprehensive comparison between the packed bed and monolith contactor configurations for direct air capture (DAC) via process modeling of a temperature-vacuum swing adsorption (TVSA) process. We investigate various design parameters to optimize performance across different contactor geometries, including pellet size, monolith wall thickness, active sorbent content in monoliths, and packed bed structure configurations, considering both a traditional long column (PB<sub>40</sub>) and multiple shorter columns configured in parallel (PB<sub>5</sub>). Our parametric analysis assesses specific exergy consumption, sorbent, and volume requirements across different operating conditions of a five-step TVSA cycle. For minimizing sorbent requirements, PB<sub>5</sub> and monoliths with over 80% sorbent loading were the best-performing contactor designs with overlapping performance in the low-exergy region. Beyond this region, PB<sub>5</sub> faced limitations in reducing sorbent requirements further and was constrained by a maximum velocity at which it is sensible to operate without substantially increasing the exergy demand. In contrast, monoliths decreased sorbent requirements with minimal exergy increase due to reduced mass transfer resistances and lower pressure drop associated with their thin walls. The analysis of volume requirement-specific exergy Pareto fronts revealed that PB<sub>5</sub> was less competitive with this metric due to the requirements for additional void space in the contactor configuration. The study also revealed that optimal sorbent loading for reducing volume requirements in monoliths differed from those minimizing sorbent usage, with the most effective loading being below 100%. Thus, the optimal contactor design varies depending on the goals of minimizing sorbent and volume requirements, and the choice and design of the contactor will depend on the relative costs of these factors. Lastly, our findings challenge the assumption that higher velocities are always preferable for direct air capture, suggesting instead that the operating velocity depends on the contactor configuration.

Authors

Institutions

Publication Details

Journal
Industrial & Engineering Chemistry Research
Published
2024-11-04
DOI
https://doi.org/10.1021/acs.iecr.4c02303
Citations
19
Primary Topic
Carbon Dioxide Capture Technologies
Type
article
Field-Weighted Citation Impact
4.04

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Exploring Geometric Properties and Cycle Design in Packed Bed and Monolith Contactors Using Temperature-Vacuum Swing Adsorption Modeling for Direct Air Capture

Marco Mazzotti, Valentina Stampi-Bombelli
19 citations
Industrial & Engineering Chemistry Research
Carbon Dioxide Capture Technologies
4.04
article

Exploring Geometric Properties and Cycle Design in Packed Bed and Monolith Contactors Using Temperature-Vacuum Swing Adsorption Modeling for Direct Air Capture

Marco Mazzotti, Valentina Stampi-Bombelli
article en
19 citations

Abstract

This study presents a comprehensive comparison between the packed bed and monolith contactor configurations for direct air capture (DAC) via process modeling of a temperature-vacuum swing adsorption (TVSA) process. We investigate various design parameters to optimize performance across different contactor geometries, including pellet size, monolith wall thickness, active sorbent content in monoliths, and packed bed structure configurations, considering both a traditional long column (PB<sub>40</sub>) and multiple shorter columns configured in parallel (PB<sub>5</sub>). Our parametric analysis assesses specific exergy consumption, sorbent, and volume requirements across different operating conditions of a five-step TVSA cycle. For minimizing sorbent requirements, PB<sub>5</sub> and monoliths with over 80% sorbent loading were the best-performing contactor designs with overlapping performance in the low-exergy region. Beyond this region, PB<sub>5</sub> faced limitations in reducing sorbent requirements further and was constrained by a maximum velocity at which it is sensible to operate without substantially increasing the exergy demand. In contrast, monoliths decreased sorbent requirements with minimal exergy increase due to reduced mass transfer resistances and lower pressure drop associated with their thin walls. The analysis of volume requirement-specific exergy Pareto fronts revealed that PB<sub>5</sub> was less competitive with this metric due to the requirements for additional void space in the contactor configuration. The study also revealed that optimal sorbent loading for reducing volume requirements in monoliths differed from those minimizing sorbent usage, with the most effective loading being below 100%. Thus, the optimal contactor design varies depending on the goals of minimizing sorbent and volume requirements, and the choice and design of the contactor will depend on the relative costs of these factors. Lastly, our findings challenge the assumption that higher velocities are always preferable for direct air capture, suggesting instead that the operating velocity depends on the contactor configuration.

Industrial & Engineering Chemistry ResearchVol. 63(45)
ETH Zurich (CH)
National Science Foundation, Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung
Affordable and clean energy
Openalex Percentile: Top 5%
Carbon Dioxide Capture Technologies
4.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.