Inter- and intra-examiner reliability of short-term measurement of heart rate variability on rest in patients hospitalized with COVID-19

Measures reflecting cardiac sympathovagal activity, particularly those associated with heart rate variability (HRV), are widely recognized and utilized in both scientific and clinical contexts. This study aimed to assess the inter- and intra-examiner reliability of short-term HRV parameters in patients hospitalized with coronavirus disease 2019 (COVID-19). A total of 103 patients (both sexes) diagnosed with COVID-19 were included in the study. HRV was analyzed using both linear and nonlinear methods. Reliability was evaluated through intraclass correlation coefficient (ICC<sub>2.1</sub>), minimum detectable change (MDC), standard error of measurement (SEM), and coefficient of variation (CV). According to Fleiss' criteria, excellent reliability was demonstrated, with ICC values ranging from 0.970 to 0.999 for Examiner 1, and from 0.956 to 0.999, for Examiner 2. In the inter-examiner analysis, the ICCs of HRV parameters ranged from 0.972 to 0.999. SEM values for intra-examiner reliability for Examiner 1 ranged from 0.02 to 5.64, with MDC values from 0.05 to 15.64, and CV (%) from 0.28 to 8.04. For Examiner 2, SEM values ranged from 0.02 to 8.18, MDC values from 0.05 to 22.68, and CV (%) from 0.24 to 8.14. For inter-examiner reliability, SEM values ranged from 0.02 to 6.17, MDC from 0.06 to 17.11, and CV (%) from 0.34 to 9.81. Across all analyses, CVs for HRV parameters remained below 10%. Considering different time points and different examiners, short-term resting HRV measurements in patients hospitalized with COVID-19, as evaluated using a portable heart rate device, exhibit high reliability.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2024-11-04
DOI
https://doi.org/10.1038/s41598-024-77558-5
Citations
2
Primary Topic
Heart Rate Variability and Autonomic Control
Type
article
Field-Weighted Citation Impact
0.80

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Inter- and intra-examiner reliability of short-term measurement of heart rate variability on rest in patients hospitalized with COVID-19

André Pontes‐Silva, Sigrid de Sousa dos Santos, Ross A Arena, Aldair Darlan Santos‐de‐Araújo et al.
2 citations
Scientific Reports
Heart Rate Variability and Autonomic Control
0.80
article

Inter- and intra-examiner reliability of short-term measurement of heart rate variability on rest in patients hospitalized with COVID-19

André Pontes‐Silva, Sigrid de Sousa dos Santos, Ross A Arena, Aldair Darlan Santos‐de‐Araújo, Daniela Bassi‐Dibai, Cyrene Piazera Silva Costa, Laíse Nunes Rodrigues, Murilo Rezende Oliveira, Shane A. Phillips, Renan Shida Marinho, Audrey Borghi-Silva
article en
2 citations

Abstract

Measures reflecting cardiac sympathovagal activity, particularly those associated with heart rate variability (HRV), are widely recognized and utilized in both scientific and clinical contexts. This study aimed to assess the inter- and intra-examiner reliability of short-term HRV parameters in patients hospitalized with coronavirus disease 2019 (COVID-19). A total of 103 patients (both sexes) diagnosed with COVID-19 were included in the study. HRV was analyzed using both linear and nonlinear methods. Reliability was evaluated through intraclass correlation coefficient (ICC<sub>2.1</sub>), minimum detectable change (MDC), standard error of measurement (SEM), and coefficient of variation (CV). According to Fleiss' criteria, excellent reliability was demonstrated, with ICC values ranging from 0.970 to 0.999 for Examiner 1, and from 0.956 to 0.999, for Examiner 2. In the inter-examiner analysis, the ICCs of HRV parameters ranged from 0.972 to 0.999. SEM values for intra-examiner reliability for Examiner 1 ranged from 0.02 to 5.64, with MDC values from 0.05 to 15.64, and CV (%) from 0.28 to 8.04. For Examiner 2, SEM values ranged from 0.02 to 8.18, MDC values from 0.05 to 22.68, and CV (%) from 0.24 to 8.14. For inter-examiner reliability, SEM values ranged from 0.02 to 6.17, MDC from 0.06 to 17.11, and CV (%) from 0.34 to 9.81. Across all analyses, CVs for HRV parameters remained below 10%. Considering different time points and different examiners, short-term resting HRV measurements in patients hospitalized with COVID-19, as evaluated using a portable heart rate device, exhibit high reliability.

Scientific ReportsVol. 14(1)
Universidade Federal de São Carlos (BR), University of Illinois Chicago (US), Universidade Ceuma (BR)
Fundação de Amparo à Pesquisa do Estado de São Paulo, Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, Conselho Nacional de Desenvolvimento Científico e Tecnológico, Fundação de Amparo à Pesquisa e ao Desenvolvimento Científico e Tecnológico do Maranhão
Good health and well-being
Openalex Percentile: Top 23%
Heart Rate Variability and Autonomic Control
0.80
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.