Relative Radiometric Correction Method Based on Temperature Normalization for Jilin1-KF02

The optical remote sensors carried by the Jilin-1 KF02 series satellites have an imaging resolution better than 0.5 m and a width of 150 km. There are radiometric problems, such as stripe noise, vignetting, and inter-slice chromatic aberration, in their raw images. In this paper, a relative radiometric correction method based on temperature normalization is proposed for the response characteristics of sensors and the structural characteristics of optical splicing of Jilin-1 KF02 series satellites cameras. Firstly, a model of temperature effect on sensor output is established to correct the variation of sensor response output digital number (DN) caused by temperature variation during imaging process, and the image is normalized to a uniform temperature reference. Then, the horizontal stripe noise of the image is eliminated by using the sensor scan line and dark pixel information, and the vertical stripe noise of the image is eliminated by using the method of on-orbit histogram statistics. Finally, the method of superposition compensation is used to correct the vignetting area at the edge of the image due to the lack of energy information received by the sensor so as to ensure the consistency of the image in color and image quality. The proposed method is verified by Jilin-1 KF02A on-orbit images. Experimental results show that the image response is uniform, the color is consistent, the average Streak Metrics (SM) is better than 0.1%, Root-Mean-Square Deviation of the Mean Line (RA) and Generalized Noise (GN) are better than 2%, Relative Average Spectral Error (RASE) and Relative Average Spectral Error (ERGAS) are greatly improved, which are better than 5% and 13, respectively, and the relative radiation quality is obviously improved after relative radiation correction.

Authors

Institutions

Publication Details

Journal
Remote Sensing
Published
2024-11-02
DOI
https://doi.org/10.3390/rs16214096
Citations
1
Primary Topic
Calibration and Measurement Techniques
Type
article
Field-Weighted Citation Impact
1.30
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Relative Radiometric Correction Method Based on Temperature Normalization for Jilin1-KF02

Yingshan Sun, Bo Zou, Xiaojie Yang, Jiangpeng Li et al.
1 citations
Remote Sensing
Calibration and Measurement Techniques
1.30
article

Relative Radiometric Correction Method Based on Temperature Normalization for Jilin1-KF02

Yingshan Sun, Bo Zou, Xiaojie Yang, Jiangpeng Li, Hongyu Wu, Song Yang, Lei Zhang, Yang Bai, Shuai Huang
article en
1 citations

Abstract

The optical remote sensors carried by the Jilin-1 KF02 series satellites have an imaging resolution better than 0.5 m and a width of 150 km. There are radiometric problems, such as stripe noise, vignetting, and inter-slice chromatic aberration, in their raw images. In this paper, a relative radiometric correction method based on temperature normalization is proposed for the response characteristics of sensors and the structural characteristics of optical splicing of Jilin-1 KF02 series satellites cameras. Firstly, a model of temperature effect on sensor output is established to correct the variation of sensor response output digital number (DN) caused by temperature variation during imaging process, and the image is normalized to a uniform temperature reference. Then, the horizontal stripe noise of the image is eliminated by using the sensor scan line and dark pixel information, and the vertical stripe noise of the image is eliminated by using the method of on-orbit histogram statistics. Finally, the method of superposition compensation is used to correct the vignetting area at the edge of the image due to the lack of energy information received by the sensor so as to ensure the consistency of the image in color and image quality. The proposed method is verified by Jilin-1 KF02A on-orbit images. Experimental results show that the image response is uniform, the color is consistent, the average Streak Metrics (SM) is better than 0.1%, Root-Mean-Square Deviation of the Mean Line (RA) and Generalized Noise (GN) are better than 2%, Relative Average Spectral Error (RASE) and Relative Average Spectral Error (ERGAS) are greatly improved, which are better than 5% and 13, respectively, and the relative radiation quality is obviously improved after relative radiation correction.

Remote SensingVol. 16(21)
Jilian Technology Group (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 12%
Calibration and Measurement Techniques
1.30
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.