X-ray diagnostics for the cavity-based x-ray free-electron laser project

The success of x-ray free-electron lasers (XFELs) in recent years has greatly advanced many scientific fields. However, most of these XFELs suffer from a low longitudinal coherence and instabilities due to the stochastic start-up process. A cavity-based x-ray free-electron laser (CBXFEL) is a possible future direction in the development of fully coherent and stable x-ray sources. One of the challenges of a CBXFEL is the requirement for the <a:math xmlns:a="http://www.w3.org/1998/Math/MathML" display="inline"><a:mrow><a:mi mathvariant="normal">μ</a:mi><a:mi mathvariant="normal">m</a:mi><a:mtext>−</a:mtext><a:mi>sized</a:mi></a:mrow></a:math> electron bunches to fully overlap in three dimensions with the circulating <e:math xmlns:e="http://www.w3.org/1998/Math/MathML" display="inline"><e:mrow><e:mi mathvariant="normal">μ</e:mi><e:mi mathvariant="normal">m</e:mi><e:mtext>−</e:mtext><e:mi>sized</e:mi></e:mrow></e:math> x-ray pulses in an x-ray cavity tens or hundreds of meters long. We present here the development of an x-ray diagnostics system for accurate alignment of x-ray beams in the CBXFEL cavity. The system was developed within the framework of a CBXFEL research and development collaboration among Argonne National Laboratory, SLAC National Accelerator Laboratory, and Spring-8. All the designed diagnostic components have been fully characterized at the Advanced Photon Source to demonstrate a capability for sub-<i:math xmlns:i="http://www.w3.org/1998/Math/MathML" display="inline"><i:mi mathvariant="normal">μ</i:mi><i:mi>rad</i:mi></i:math> angular and <l:math xmlns:l="http://www.w3.org/1998/Math/MathML" display="inline"><l:mrow><l:mi mathvariant="normal">μ</l:mi><l:mi mathvariant="normal">m</l:mi></l:mrow></l:math> spatial alignment of the CBXFEL cavity. Published by the American Physical Society 2024

Authors

Institutions

Publication Details

Journal
Physical Review Accelerators and Beams
Published
2024-11-04
DOI
https://doi.org/10.1103/physrevaccelbeams.27.110701
Citations
1
Primary Topic
Particle Accelerators and Free-Electron Lasers
Type
article
Field-Weighted Citation Impact
0.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

X-ray diagnostics for the cavity-based x-ray free-electron laser project

Keenan Lang, Rachel Margraf, Yuri Shvyd’ko, Donald A. Walko et al.
1 citations
Physical Review Accelerators and Beams
Particle Accelerators and Free-Electron Lasers
0.21
article

X-ray diagnostics for the cavity-based x-ray free-electron laser project

Keenan Lang, Rachel Margraf, Yuri Shvyd’ko, Donald A. Walko, P. C. Pradhan, Antonino Miceli, Takahiro Sato, Aliaksei Halavanau, Joseph Sullivan, Peifan Liu, Mario Balcazar, Mark L. Rivers, Anne Sakdinawat, D. Shu, Kenan Li, Diling Zhu
article en
1 citations

Abstract

The success of x-ray free-electron lasers (XFELs) in recent years has greatly advanced many scientific fields. However, most of these XFELs suffer from a low longitudinal coherence and instabilities due to the stochastic start-up process. A cavity-based x-ray free-electron laser (CBXFEL) is a possible future direction in the development of fully coherent and stable x-ray sources. One of the challenges of a CBXFEL is the requirement for the <a:math xmlns:a="http://www.w3.org/1998/Math/MathML" display="inline"><a:mrow><a:mi mathvariant="normal">μ</a:mi><a:mi mathvariant="normal">m</a:mi><a:mtext>−</a:mtext><a:mi>sized</a:mi></a:mrow></a:math> electron bunches to fully overlap in three dimensions with the circulating <e:math xmlns:e="http://www.w3.org/1998/Math/MathML" display="inline"><e:mrow><e:mi mathvariant="normal">μ</e:mi><e:mi mathvariant="normal">m</e:mi><e:mtext>−</e:mtext><e:mi>sized</e:mi></e:mrow></e:math> x-ray pulses in an x-ray cavity tens or hundreds of meters long. We present here the development of an x-ray diagnostics system for accurate alignment of x-ray beams in the CBXFEL cavity. The system was developed within the framework of a CBXFEL research and development collaboration among Argonne National Laboratory, SLAC National Accelerator Laboratory, and Spring-8. All the designed diagnostic components have been fully characterized at the Advanced Photon Source to demonstrate a capability for sub-<i:math xmlns:i="http://www.w3.org/1998/Math/MathML" display="inline"><i:mi mathvariant="normal">μ</i:mi><i:mi>rad</i:mi></i:math> angular and <l:math xmlns:l="http://www.w3.org/1998/Math/MathML" display="inline"><l:mrow><l:mi mathvariant="normal">μ</l:mi><l:mi mathvariant="normal">m</l:mi></l:mrow></l:math> spatial alignment of the CBXFEL cavity. Published by the American Physical Society 2024

Physical Review Accelerators and BeamsVol. 27(11)
Argonne National Laboratory (US), SLAC National Accelerator Laboratory (US), University of Chicago (US)
U.S. Department of Energy, UK Atomic Energy Authority, Office of Science, Basic Energy Sciences, Argonne National Laboratory, Los Alamos National Laboratory, SLAC National Accelerator Laboratory
Openalex Percentile: Top 46%
Particle Accelerators and Free-Electron Lasers
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.