Current Compensation for Faulted Grid-Connected PV Arrays Using a Modified Voltage-Fed Quasi-Z-Source Inverter

Large-scale photovoltaic (PV) systems are being widely deployed to meet global environmental goals and renewable energy targets. Advances in PV technology have driven investment in the electric sector. However, as the size of PV arrays grows, more obstacles and challenges emerge. The primary obstacles are the occurrence of direct current (DC) faults and shading in a large array of PV panels, where any malfunction in a single panel can have a detrimental impact on the overall output power of the entire series-connected PV string and therefore the PV array. Due to the abrupt and frequent fluctuations in power, beside the low-PV systems’ moment of inertia, various technical problems may arise at the point of common coupling (PCC) of grid-connected PV generations, such as frequency and voltage stability, power efficiency, voltage sag, harmonic distortion, and other power quality factors. The majority of the suggested solutions were deficient in several crucial transient operating features and cost feasibility; therefore, this paper introduces a novel power electronic DC–DC converter that seeks to mitigate these effects by compensating for the decrease in current on the DC side of the system. The suggested solution was derived from the dual-source voltage-fed quasi-Z-source inverter (VF-qZSI), where the PV generation power can be supported by an energy storage element. This paper also presents the system architecture and the corresponding power switching control. The feasibility of the proposed method is investigated with real field data and the PSCAD simulation platform during all possible weather conditions and array faults. The results demonstrate the feasibility and capability of the proposed scheme, which contributes in suppressing the peak of the transient power-to-time variation (dP/dt) by 72% and reducing its normalized root-mean-square error by about 38%, with an AC current total harmonic distortion (THD) of only 1.04%.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2024-11-02
DOI
https://doi.org/10.3390/electronics13214312
Citations
3
Primary Topic
Photovoltaic System Optimization Techniques
Type
article
Field-Weighted Citation Impact
0.31
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Current Compensation for Faulted Grid-Connected PV Arrays Using a Modified Voltage-Fed Quasi-Z-Source Inverter

Faris E. Alfaris, Abdullah Abdurrahman Al-Saloli
3 citations
Electronics
Photovoltaic System Optimization Techniques
0.31
article

Current Compensation for Faulted Grid-Connected PV Arrays Using a Modified Voltage-Fed Quasi-Z-Source Inverter

Faris E. Alfaris, Abdullah Abdurrahman Al-Saloli
article en
3 citations

Abstract

Large-scale photovoltaic (PV) systems are being widely deployed to meet global environmental goals and renewable energy targets. Advances in PV technology have driven investment in the electric sector. However, as the size of PV arrays grows, more obstacles and challenges emerge. The primary obstacles are the occurrence of direct current (DC) faults and shading in a large array of PV panels, where any malfunction in a single panel can have a detrimental impact on the overall output power of the entire series-connected PV string and therefore the PV array. Due to the abrupt and frequent fluctuations in power, beside the low-PV systems’ moment of inertia, various technical problems may arise at the point of common coupling (PCC) of grid-connected PV generations, such as frequency and voltage stability, power efficiency, voltage sag, harmonic distortion, and other power quality factors. The majority of the suggested solutions were deficient in several crucial transient operating features and cost feasibility; therefore, this paper introduces a novel power electronic DC–DC converter that seeks to mitigate these effects by compensating for the decrease in current on the DC side of the system. The suggested solution was derived from the dual-source voltage-fed quasi-Z-source inverter (VF-qZSI), where the PV generation power can be supported by an energy storage element. This paper also presents the system architecture and the corresponding power switching control. The feasibility of the proposed method is investigated with real field data and the PSCAD simulation platform during all possible weather conditions and array faults. The results demonstrate the feasibility and capability of the proposed scheme, which contributes in suppressing the peak of the transient power-to-time variation (dP/dt) by 72% and reducing its normalized root-mean-square error by about 38%, with an AC current total harmonic distortion (THD) of only 1.04%.

ElectronicsVol. 13(21)
King Saud University (SA)
Affordable and clean energy
Openalex Percentile: Top 52%
Photovoltaic System Optimization Techniques
0.31
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.