Experimental and Numerical Studies of the Temperature Field in a Dielectrophoretic Cell Separation Device Subject to Joule Heating

Technologies for rapid and high-throughput separation of rare cells from large populations of other types of cells have recently attracted much attention in the field of bioengineering. Among the various cell separation technologies proposed in the past, dielectrophoresis has shown particular promise because of its preciseness of manipulation and noninvasiveness to cells. However, one drawback of dielectrophoresis devices is that their application of high voltage generates Joule heat that exposes the cells within the device to high temperatures. To further explore this problem, this study investigated the temperature field in a previously developed cell separation device in detail. The temperature rise at the bottom of the microfluidic channel in the device was measured using a micro-LIF method. Moreover, the thermofluidic behavior of the cell separation device was numerically investigated by adopting a heat generation model that takes the electric-field-dependent heat generation term into account in the energy equation. Under the operating conditions of the previously developed cell separation device, the experimentally obtained temperature rise in the device was approximately 20 °C, and the numerical simulation results generally agreed well. Next, parametric calculations were performed with changes in the flow rate of the cell sample solution and the solution conductivity, and a temperature increase of more than 40 °C was predicted. The results demonstrated that an increase in temperature within the cell separation device may have a significant impact on the physiological functions of the cells, depending on the operating conditions of the device.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2024-11-04
DOI
https://doi.org/10.3390/s24217098
Citations
1
Primary Topic
Microfluidic and Bio-sensing Technologies
Type
article
Field-Weighted Citation Impact
0.18
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental and Numerical Studies of the Temperature Field in a Dielectrophoretic Cell Separation Device Subject to Joule Heating

Shigeru Tada, Yoshinori Seki
1 citations
Sensors
Microfluidic and Bio-sensing Technologies
0.18
article

Experimental and Numerical Studies of the Temperature Field in a Dielectrophoretic Cell Separation Device Subject to Joule Heating

Shigeru Tada, Yoshinori Seki
article en
1 citations

Abstract

Technologies for rapid and high-throughput separation of rare cells from large populations of other types of cells have recently attracted much attention in the field of bioengineering. Among the various cell separation technologies proposed in the past, dielectrophoresis has shown particular promise because of its preciseness of manipulation and noninvasiveness to cells. However, one drawback of dielectrophoresis devices is that their application of high voltage generates Joule heat that exposes the cells within the device to high temperatures. To further explore this problem, this study investigated the temperature field in a previously developed cell separation device in detail. The temperature rise at the bottom of the microfluidic channel in the device was measured using a micro-LIF method. Moreover, the thermofluidic behavior of the cell separation device was numerically investigated by adopting a heat generation model that takes the electric-field-dependent heat generation term into account in the energy equation. Under the operating conditions of the previously developed cell separation device, the experimentally obtained temperature rise in the device was approximately 20 °C, and the numerical simulation results generally agreed well. Next, parametric calculations were performed with changes in the flow rate of the cell sample solution and the solution conductivity, and a temperature increase of more than 40 °C was predicted. The results demonstrated that an increase in temperature within the cell separation device may have a significant impact on the physiological functions of the cells, depending on the operating conditions of the device.

SensorsVol. 24(21)
National Defense Academy of Japan (JP)
Affordable and clean energy
Openalex Percentile: Top 51%
Microfluidic and Bio-sensing Technologies
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Experimental and Numerical Studies of the Temperature Field in a Dielectrophoretic Cell Separation Device Subject to Joule Heating — Shigeru Tada, Yoshinori Seki · Sensors (2024) | TGRS Research Map | TGRS