Influence of Reclaimed Water on the Visual Quality of Automotive Coating

In the present study, the possibility of recovering water in a car wash station was presented. The resistance of automotive coatings to washing water recovered at 50% and 70% from wastewater generated at car wash was tested. Wastewater treatment was carried out by ultrafiltration (UF) using tubular polyvinylidene fluoride (PVDF) membranes (100 and 200 kDa) manufactured by the PCI company. The membranes retained oil contamination, suspended solids, and over 60% of surfactants. For comparison, the 0.5% Turbo Active Green solution, used at professional car washes, was also applied in paint resistance studies. The tested solutions washed the painted surfaces of samples taken from car doors for 8 days. The resistance of automotive coatings to washing solutions was assessed by measuring gloss, Log Haze, RIQ, and Rspec parameters. Scratch resistance was also assessed. The results obtained in the current study indicated that the use of water recovered from wastewater did not deteriorate the quality of the car paint coating.

Authors

Institutions

Publication Details

Journal
Materials
Published
2024-11-04
DOI
https://doi.org/10.3390/ma17215382
Citations
3
Primary Topic
Surface Modification and Superhydrophobicity
Type
article
Field-Weighted Citation Impact
0.54
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of Reclaimed Water on the Visual Quality of Automotive Coating

Marek Gryta, Piotr Woźniak
3 citations
Materials
Surface Modification and Superhydrophobicity
0.54
article

Influence of Reclaimed Water on the Visual Quality of Automotive Coating

Marek Gryta, Piotr Woźniak
article en
3 citations

Abstract

In the present study, the possibility of recovering water in a car wash station was presented. The resistance of automotive coatings to washing water recovered at 50% and 70% from wastewater generated at car wash was tested. Wastewater treatment was carried out by ultrafiltration (UF) using tubular polyvinylidene fluoride (PVDF) membranes (100 and 200 kDa) manufactured by the PCI company. The membranes retained oil contamination, suspended solids, and over 60% of surfactants. For comparison, the 0.5% Turbo Active Green solution, used at professional car washes, was also applied in paint resistance studies. The tested solutions washed the painted surfaces of samples taken from car doors for 8 days. The resistance of automotive coatings to washing solutions was assessed by measuring gloss, Log Haze, RIQ, and Rspec parameters. Scratch resistance was also assessed. The results obtained in the current study indicated that the use of water recovered from wastewater did not deteriorate the quality of the car paint coating.

MaterialsVol. 17(21)
West Pomeranian University of Technology in Szczecin (PL)
Clean water and sanitation
Openalex Percentile: Top 38%
Surface Modification and Superhydrophobicity
0.54
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.