Measurement of tepotinib by UPLC‒MS/MS and its interaction with naringenin in rats

We established a method based on ultra performance liquid chromatography tandem mass spectrometry (UPLC‒MS/MS) to quantitatively measure tepotinib, which was validated as acceptable and used in the evaluation of food-drug interactions between tepotinib and naringenin in rats. We used pemigatinib as the internal standard (IS), and acetonitrile and 0.1% formic acid aqueous solution constituted the mobile phase. To extract the target analyte, acetonitrile was used for protein precipitation (PPT). For UPLC‒MS/MS, we performed liquid chromatography using a C18 column, and mass spectrometry was performed in positive multiple reaction monitoring (MRM) mode. Excellent linearity was shown in the range of 0.1-500 ng/mL, and the coefficient of correlation was > 0.99. Notably, the lower limit of quantification (LLOQ) for tepotinib was determined to be 0.1 ng/mL. The intra- and inter-day accuracy of tepotinib ranged from - 1.7 to 7.3%, while the precision was ≤ 8.4%, at three concentrations except LLOQ. The recovery of each substance was ≥ 81.2%, and the matrix effects were within 90.5-98.6%. The stabilities of all analytes under different conditions met all requirements for quantitation in plasma samples. The relevant parameters, such as LLOQ, were evaluated in accordance with the principles of the Food and Drug Administration (FDA) biological verification method. Food-drug interaction study had shown that the plasma concentration of tepotinib could be significantly increased, accompanied by a decrease in clearance rate when administered with 50 mg/kg naringenin. The results showed that naringenin could increase the plasma concentration and decrease the clearance rate of tepotinib when naringenin and tepotinib were administered at the same time.

Authors

Institutions

Publication Details

Journal
BMC Chemistry
Published
2024-11-04
DOI
https://doi.org/10.1186/s13065-024-01293-1
Primary Topic
Chronic Myeloid Leukemia Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measurement of tepotinib by UPLC‒MS/MS and its interaction with naringenin in rats

Zhe Chen, Shunbin Luo, Chaojie Chen, Yanan Liu et al.
BMC Chemistry
Chronic Myeloid Leukemia Treatments
article

Measurement of tepotinib by UPLC‒MS/MS and its interaction with naringenin in rats

Zhe Chen, Shunbin Luo, Chaojie Chen, Yanan Liu, Xinhao Xu
article en

Abstract

We established a method based on ultra performance liquid chromatography tandem mass spectrometry (UPLC‒MS/MS) to quantitatively measure tepotinib, which was validated as acceptable and used in the evaluation of food-drug interactions between tepotinib and naringenin in rats. We used pemigatinib as the internal standard (IS), and acetonitrile and 0.1% formic acid aqueous solution constituted the mobile phase. To extract the target analyte, acetonitrile was used for protein precipitation (PPT). For UPLC‒MS/MS, we performed liquid chromatography using a C18 column, and mass spectrometry was performed in positive multiple reaction monitoring (MRM) mode. Excellent linearity was shown in the range of 0.1-500 ng/mL, and the coefficient of correlation was > 0.99. Notably, the lower limit of quantification (LLOQ) for tepotinib was determined to be 0.1 ng/mL. The intra- and inter-day accuracy of tepotinib ranged from - 1.7 to 7.3%, while the precision was ≤ 8.4%, at three concentrations except LLOQ. The recovery of each substance was ≥ 81.2%, and the matrix effects were within 90.5-98.6%. The stabilities of all analytes under different conditions met all requirements for quantitation in plasma samples. The relevant parameters, such as LLOQ, were evaluated in accordance with the principles of the Food and Drug Administration (FDA) biological verification method. Food-drug interaction study had shown that the plasma concentration of tepotinib could be significantly increased, accompanied by a decrease in clearance rate when administered with 50 mg/kg naringenin. The results showed that naringenin could increase the plasma concentration and decrease the clearance rate of tepotinib when naringenin and tepotinib were administered at the same time.

BMC ChemistryVol. 18(1)
Wenzhou Medical University (CN), First Affiliated Hospital of Wenzhou Medical University (CN), Lishui City People's Hospital (CN), Wenzhou City People's Hospital (CN)
Zero hunger
Openalex Percentile: Top 68%
Chronic Myeloid Leukemia Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.