Optimization Method of Inductive Reactive Power Compensation Scheme for Regional 220kV Power Grid

Voltage and reactive power control is becoming an increasingly urgent task as the complexity of electric power systems (EPS) increases, power transmission increases and various types of generation are connected to high voltage levels. Maintaining and enhancing power quality is the main concern in power systems. Based on the annual voltage of the 220kV substations, the standard deviation of the average voltage and the upper voltage control limit of the substations are calculated to analyze the regional reactive power compensation and demands in this paper. Then, the inductive reactive power compensation capacity of the substation is calculated according to the outgoing line charging power of the substation. Combined with the configured reactive power compensation capacity of 220kV substations, the demand for reactive power capacity of each 220kV substation is calculated. Finally, the index of inductive reactive power compensation of the 220kV substation is defined and the objective function is established. The effectiveness and adaptability of the proposed method are verified by a regional power grid.

Authors

Institutions

Publication Details

Published
2024-09-20
DOI
https://doi.org/10.1109/itnec60942.2024.10732933
Primary Topic
High-Voltage Power Transmission Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization Method of Inductive Reactive Power Compensation Scheme for Regional 220kV Power Grid

Canlin Wang, Shiyao Jiang, Mengjiao Li, Yuzheng Xie
High-Voltage Power Transmission Systems
article

Optimization Method of Inductive Reactive Power Compensation Scheme for Regional 220kV Power Grid

Canlin Wang, Shiyao Jiang, Mengjiao Li, Yuzheng Xie
article en

Abstract

Voltage and reactive power control is becoming an increasingly urgent task as the complexity of electric power systems (EPS) increases, power transmission increases and various types of generation are connected to high voltage levels. Maintaining and enhancing power quality is the main concern in power systems. Based on the annual voltage of the 220kV substations, the standard deviation of the average voltage and the upper voltage control limit of the substations are calculated to analyze the regional reactive power compensation and demands in this paper. Then, the inductive reactive power compensation capacity of the substation is calculated according to the outgoing line charging power of the substation. Combined with the configured reactive power compensation capacity of 220kV substations, the demand for reactive power capacity of each 220kV substation is calculated. Finally, the index of inductive reactive power compensation of the 220kV substation is defined and the objective function is established. The effectiveness and adaptability of the proposed method are verified by a regional power grid.

Hunan Xiangdian Test Research Institute (China) (CN), State Grid Hunan Electric Power Company Limited (CN)
Affordable and clean energy
Openalex Percentile: Top 83%
High-Voltage Power Transmission Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.