Partial Discharge Location Method of Oil-Immersed Transformer Based on EFPI Sensor

The detection of partial discharge of oil-immersed transformer mainly includes pulse current method, ultra high frequency method and ultrasonic method. Among them, ultrasonic method has the advantages of safety, insulation and anti-electromagnetic interference. It is suitable for installation in the interior of oil-immersed transformer, PD online monitoring, and has a development prospect. In order to study the positioning method of partial discharge in oil-immersed transformer, an improved pressure balance optical fiber EFPI sensor is proposed and a positioning system of partial discharge in oil-immersed transformer is built. The results show that the improved pressure balance EFPI sensor is not affected by the difference of temperature and pressure, the error of detection signal can be controlled within 7%, and the positioning accuracy can reach centimeter level. The research in this paper can provide theory and method support for local discharge monitoring of oil-immersed transformer.

Authors

Institutions

Publication Details

Published
2024-09-20
DOI
https://doi.org/10.1109/itnec60942.2024.10733138
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Partial Discharge Location Method of Oil-Immersed Transformer Based on EFPI Sensor

Tieyuan Zhu, Hongjun Zhou, Wei Qi, Rui Dai
High voltage insulation and dielectric phenomena
article

Partial Discharge Location Method of Oil-Immersed Transformer Based on EFPI Sensor

Tieyuan Zhu, Hongjun Zhou, Wei Qi, Rui Dai
article en

Abstract

The detection of partial discharge of oil-immersed transformer mainly includes pulse current method, ultra high frequency method and ultrasonic method. Among them, ultrasonic method has the advantages of safety, insulation and anti-electromagnetic interference. It is suitable for installation in the interior of oil-immersed transformer, PD online monitoring, and has a development prospect. In order to study the positioning method of partial discharge in oil-immersed transformer, an improved pressure balance optical fiber EFPI sensor is proposed and a positioning system of partial discharge in oil-immersed transformer is built. The results show that the improved pressure balance EFPI sensor is not affected by the difference of temperature and pressure, the error of detection signal can be controlled within 7%, and the positioning accuracy can reach centimeter level. The research in this paper can provide theory and method support for local discharge monitoring of oil-immersed transformer.

Shanghai Electric (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 88%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Partial Discharge Location Method of Oil-Immersed Transformer Based on EFPI Sensor — Tieyuan Zhu, Hongjun Zhou, et al. · (2024) | TGRS Research Map | TGRS