Development of a Protocol for Verification Test on Critical Care Ventilators

Ventilators are used to help patients with respiratory failure, being life support, they should be checked periodically. This article discusses the need for a standardized protocol to verify the correct functioning of mechanical critical care ventilators. To this end, a protocol was developed based on the UNE-EN ISO 80601:2:2021 Standard. Based on the calculation of the measurement uncertainty, the accuracy and reliability of the fan measurements is guaranteed. The parameters analyzed are tidal volume (VT), respiratory rate (RR), inspiratory time (IT), complacency and positive end expiratory pressure (PEEP). The trials were conducted on ventilators currently in use and using an analyzer and a test lung. Finally, tables were developed to present the measured data in a clear and orderly manner. This protocol is expected to be an aid tool in medical equipment testing laboratories.

Authors

Institutions

Publication Details

Published
2024-09-18
DOI
https://doi.org/10.1109/argencon62399.2024.10735894
Primary Topic
Respiratory Support and Mechanisms
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a Protocol for Verification Test on Critical Care Ventilators

Gabriel Albieri Quiroga, Raúl Romo, Cintia Páez, Ana Luz Treo et al.
Respiratory Support and Mechanisms
article

Development of a Protocol for Verification Test on Critical Care Ventilators

Gabriel Albieri Quiroga, Raúl Romo, Cintia Páez, Ana Luz Treo, Adrián Guasberti
article en

Abstract

Ventilators are used to help patients with respiratory failure, being life support, they should be checked periodically. This article discusses the need for a standardized protocol to verify the correct functioning of mechanical critical care ventilators. To this end, a protocol was developed based on the UNE-EN ISO 80601:2:2021 Standard. Based on the calculation of the measurement uncertainty, the accuracy and reliability of the fan measurements is guaranteed. The parameters analyzed are tidal volume (VT), respiratory rate (RR), inspiratory time (IT), complacency and positive end expiratory pressure (PEEP). The trials were conducted on ventilators currently in use and using an analyzer and a test lung. Finally, tables were developed to present the measured data in a clear and orderly manner. This protocol is expected to be an aid tool in medical equipment testing laboratories.

National University of San Juan (AR)
Affordable and clean energy
Openalex Percentile: Top 64%
Respiratory Support and Mechanisms
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.