Rotary Axis Calibration Method Based on Marker

Line laser rotary scanning reconstruction is a popular 3D reconstruction method. The camera and laser are mounted on a rotating arm, and the camera acquires the laser line information while the laser line sweeps over the object surface, stitching each frame of the point cloud obtained during the rotation process into a complete 3D model. The positional relationship between the camera and the rotation axis is unknown during the process, and calibration is required to obtain the transformation relationship between the two devices. This paper proposes a new method to calibrate the relationship between the camera and the rotation axis using man-made Markers, which ensures that the 3D point cloud data obtained by the camera can be transformed into the rotation axis coordinate system with high precision and accuracy. The calibration results of this method are applied to a laser line rotation scanning system, and good reconstruction results are achieved.

Authors

Institutions

Publication Details

Published
2024-09-20
DOI
https://doi.org/10.1109/itnec60942.2024.10733111
Primary Topic
Advanced Measurement and Detection Methods
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rotary Axis Calibration Method Based on Marker

Xiaochen Shi, Jiawei Wang, Zhihao Zhu
Advanced Measurement and Detection Methods
article

Rotary Axis Calibration Method Based on Marker

Xiaochen Shi, Jiawei Wang, Zhihao Zhu
article en

Abstract

Line laser rotary scanning reconstruction is a popular 3D reconstruction method. The camera and laser are mounted on a rotating arm, and the camera acquires the laser line information while the laser line sweeps over the object surface, stitching each frame of the point cloud obtained during the rotation process into a complete 3D model. The positional relationship between the camera and the rotation axis is unknown during the process, and calibration is required to obtain the transformation relationship between the two devices. This paper proposes a new method to calibrate the relationship between the camera and the rotation axis using man-made Markers, which ensures that the 3D point cloud data obtained by the camera can be transformed into the rotation axis coordinate system with high precision and accuracy. The calibration results of this method are applied to a laser line rotation scanning system, and good reconstruction results are achieved.

Ocean University of China (CN)
Affordable and clean energy
Openalex Percentile: Top 83%
Advanced Measurement and Detection Methods
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.