Power Quality Improvement Using Three Phase Three Wire Shunt Active Power Filter

The use of harmonic polluting loads is increasing and is creating power quality issues in the grid. The presence of harmonic pollution causes communication line interference, equipment damage, and losses in power production. Thus, increased harmonics problems necessitate focus while there are numerous tools available for reducing the impact of harmonics. In this paper a three-wire, three-phase, shunt active power filter that operates using unit template control algorithm is proposed to mitigate the harmonic distortion in the in the grid. The suggested shunt active power filter control algorithm easily maintains a self-supporting DC bus. The PWM switching signals are generated by the Current Controller. The passive power filter is also implemented for comparison purpose. The MATLAB/Simulink environment is used to implement the control strategy. The simulation results show that the shunt active power filter significantly reduces harmonics as compared to a passive power filter.

Authors

Institutions

Publication Details

Published
2024-08-29
DOI
https://doi.org/10.1109/iceect61758.2024.10739013
Citations
2
Primary Topic
Power Quality and Harmonics
Type
article
Field-Weighted Citation Impact
0.42
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Power Quality Improvement Using Three Phase Three Wire Shunt Active Power Filter

Deepak Gautam, N.A. Yusuf, Pratima Walde, Sushma Kakkar
2 citations
Power Quality and Harmonics
0.42
article

Power Quality Improvement Using Three Phase Three Wire Shunt Active Power Filter

Deepak Gautam, N.A. Yusuf, Pratima Walde, Sushma Kakkar
article en
2 citations

Abstract

The use of harmonic polluting loads is increasing and is creating power quality issues in the grid. The presence of harmonic pollution causes communication line interference, equipment damage, and losses in power production. Thus, increased harmonics problems necessitate focus while there are numerous tools available for reducing the impact of harmonics. In this paper a three-wire, three-phase, shunt active power filter that operates using unit template control algorithm is proposed to mitigate the harmonic distortion in the in the grid. The suggested shunt active power filter control algorithm easily maintains a self-supporting DC bus. The PWM switching signals are generated by the Current Controller. The passive power filter is also implemented for comparison purpose. The MATLAB/Simulink environment is used to implement the control strategy. The simulation results show that the shunt active power filter significantly reduces harmonics as compared to a passive power filter.

Sharda University (IN)
Affordable and clean energy
Openalex Percentile: Top 37%
Power Quality and Harmonics
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Power Quality Improvement Using Three Phase Three Wire Shunt Active Power Filter — Deepak Gautam, N.A. Yusuf, et al. · (2024) | TGRS Research Map | TGRS