Increasing energy-efficiency of microheating in handheld nucleic acid amplification tests

Pocket-sized isothermal nucleic acid amplification tests (NAATs) have shown significant promise during the recent SARS-CoV-2 pandemic to decentralize diagnostics and increase the speed of detection. However, a key technical challenge is solving heating in an energy-efficient, robust and scalable manner. This work presents a novel top-down heating approach using PCB trace heaters and metal heat spreaders integrated into the microreactors, optimized through experimental and simulated thermal analysis. In simulations, the effect of vertical geometry and material composition were evaluated, as well as the effect of heat spreader geometry. Experimental thermal transient analysis focused on evaluating operational performance at ambient temperature limits expected in home, office and clinical use. The design achieved reliable operation at ambient temperatures of 15-30°C with a steady-state error <1°C and average power consumption of 1W and could be powered from any USB3.0+ compliant port.

Authors

Publication Details

Published
2024-10-02
DOI
https://doi.org/10.1109/bec61458.2024.10737951
Primary Topic
Microfluidic and Capillary Electrophoresis Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Increasing energy-efficiency of microheating in handheld nucleic acid amplification tests

Tamás Párdy, Marko Lehes
Microfluidic and Capillary Electrophoresis Applications
article

Increasing energy-efficiency of microheating in handheld nucleic acid amplification tests

Tamás Párdy, Marko Lehes
article en

Abstract

Pocket-sized isothermal nucleic acid amplification tests (NAATs) have shown significant promise during the recent SARS-CoV-2 pandemic to decentralize diagnostics and increase the speed of detection. However, a key technical challenge is solving heating in an energy-efficient, robust and scalable manner. This work presents a novel top-down heating approach using PCB trace heaters and metal heat spreaders integrated into the microreactors, optimized through experimental and simulated thermal analysis. In simulations, the effect of vertical geometry and material composition were evaluated, as well as the effect of heat spreader geometry. Experimental thermal transient analysis focused on evaluating operational performance at ambient temperature limits expected in home, office and clinical use. The design achieved reliable operation at ambient temperatures of 15-30°C with a steady-state error <1°C and average power consumption of 1W and could be powered from any USB3.0+ compliant port.

Affordable and clean energy
Openalex Percentile: Top 82%
Microfluidic and Capillary Electrophoresis Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.