Dynamic Sub-Array Selection-Based Energy-Efficient Localization and Tracking Method to Power Implanted Medical Devices in Scattering Heterogenous Media Employing Ultrasound

Ultrasound (US) as a wireless power transfer methodology has drawn considerable attention from the implantable medical devices (IMD) research community. Beamforming (BF) using an external transducer array patch (ETAP) has been proposed as a robust localization scheme to find a mm-sized IMD inside the human body. However, for applications focusing on deep and shallow IMDs, optimum resource utilization at the ETAP is a major power efficiency concern for energy-constrained wearable patches. Moreover, misalignment tolerance due to IMD movements (respiratory and patient ambulatory reasons) relative to the ETAP remains a challenge. This paper presents an energy-efficient method to localize a mm-sized IMD through the dynamic selection of a sub-array within the ETAP. It is fully adaptive to the heterogeneity of the media and requires no a priori knowledge of the IMD. To improve the tolerance to IMD movements, tracking is implemented by adding and subtracting elements on the sub-array such that the sub-array electrically follows the IMD movement. Furthermore, it is shown that a minimum sampling frequency of 10X the US frequency can improve the tolerance to random noise. K-wave simulations in MATLAB are performed in different heterogenous, scattering biological media to prove the efficacy of the proposed method over standard BF methods. Measurement results in heterogenous scattering media consisting of a 3D-printed human ribs phantom and a partially blocking multipath cancellous bone phantom show an energy efficiency improvement of 10.53X and 14.4X compared to the delay-and-sum beamforming method and the unfocused transmission employing all the elements of the ETAP, respectively.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Biomedical Circuits and Systems
Published
2024-11-04
DOI
https://doi.org/10.1109/tbcas.2024.3487782
Citations
1
Primary Topic
Wireless Body Area Networks
Type
article
Field-Weighted Citation Impact
0.18
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dynamic Sub-Array Selection-Based Energy-Efficient Localization and Tracking Method to Power Implanted Medical Devices in Scattering Heterogenous Media Employing Ultrasound

Nick Van Helleputte, Georges Gielen, Stefano Stanzione, Oguz Kaan Erden et al.
1 citations
IEEE Transactions on Biomedical Circuits and Systems
Wireless Body Area Networks
0.18
article

Dynamic Sub-Array Selection-Based Energy-Efficient Localization and Tracking Method to Power Implanted Medical Devices in Scattering Heterogenous Media Employing Ultrasound

Nick Van Helleputte, Georges Gielen, Stefano Stanzione, Oguz Kaan Erden, Anirudh Kumar Parag, Fabian Beutel, Chris Van Hoof, Bogdan Raducanu, Chinmay Pendse
article en
1 citations

Abstract

Ultrasound (US) as a wireless power transfer methodology has drawn considerable attention from the implantable medical devices (IMD) research community. Beamforming (BF) using an external transducer array patch (ETAP) has been proposed as a robust localization scheme to find a mm-sized IMD inside the human body. However, for applications focusing on deep and shallow IMDs, optimum resource utilization at the ETAP is a major power efficiency concern for energy-constrained wearable patches. Moreover, misalignment tolerance due to IMD movements (respiratory and patient ambulatory reasons) relative to the ETAP remains a challenge. This paper presents an energy-efficient method to localize a mm-sized IMD through the dynamic selection of a sub-array within the ETAP. It is fully adaptive to the heterogeneity of the media and requires no a priori knowledge of the IMD. To improve the tolerance to IMD movements, tracking is implemented by adding and subtracting elements on the sub-array such that the sub-array electrically follows the IMD movement. Furthermore, it is shown that a minimum sampling frequency of 10X the US frequency can improve the tolerance to random noise. K-wave simulations in MATLAB are performed in different heterogenous, scattering biological media to prove the efficacy of the proposed method over standard BF methods. Measurement results in heterogenous scattering media consisting of a 3D-printed human ribs phantom and a partially blocking multipath cancellous bone phantom show an energy efficiency improvement of 10.53X and 14.4X compared to the delay-and-sum beamforming method and the unfocused transmission employing all the elements of the ETAP, respectively.

IEEE Transactions on Biomedical Circuits and SystemsVol. 19(3)
Imec the Netherlands (NL), IMEC (BE)
Affordable and clean energy
Openalex Percentile: Top 51%
Wireless Body Area Networks
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.