BP3: Improving Cuff-less Blood Pressure Monitoring Performance by Fusing mmWave Pulse Wave Sensing and Physiological Factors

Cuff-less methods, especially pulse wave analysis (PWA) techniques with PPG/mmWave sensing, have shown great potential for non-intrusive blood pressure (BP) monitoring. However, the state-of-the-art solutions are only validated on small-scale healthy subjects, neglecting patients with abnormal BP and thus a more urgent need for BP monitoring. To bridge the gap, we first build the largest mmWave-BP dataset to our knowledge, including 930 real patients with cardiovascular diseases, and perform extensive experiments, which reveals that all existing PWA methods exhibit far less satisfactory performance with standard deviation errors (STD) exceeding 16 mmHg for systolic BP (SBP) and 11mmHg for diastolic BP (DBP). An in-depth investigation shows that physiological factors have complex effect on vascular elasticity and structure, thus people with very different BP values may exhibit extremely similar pulse waveform, which leads to confusion in model learning. In this work, we propose BP3, which fuses physiological factors into sensing-data-driven deep-learning framework, so as to capture the intricate effect of physiological factors during the whole process of learning pulse waveforms. Evaluation results show that BP3 achieves the mean errors of-1.57 mmHg and -0.34 mmHg, STD of 9.77 mmHg and 7.93 mmHg for SBP and DBP, respectively. Moreover importantly, BP3 shows remarkable gain particularly for subjects with abnormal BP, achieving mean errors that are only 0.48% ~ 20.86% of the state-of-the-art solutions.

Authors

Institutions

Publication Details

Published
2024-11-04
DOI
https://doi.org/10.1145/3666025.3699370
Citations
11
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
2.03
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

BP3: Improving Cuff-less Blood Pressure Monitoring Performance by Fusing mmWave Pulse Wave Sensing and Physiological Factors

Jingjia Wang, Anfu Zhou, Yumeng Liang, Rui Lyu et al.
11 citations
Non-Invasive Vital Sign Monitoring
2.03
article

BP3: Improving Cuff-less Blood Pressure Monitoring Performance by Fusing mmWave Pulse Wave Sensing and Physiological Factors

Jingjia Wang, Anfu Zhou, Yumeng Liang, Rui Lyu, Huadóng Ma, Zixin Zheng, Bao Junjie, Yiwen Huang, Xiangbin Meng, Yida Tang, Chunli Shao, Qian Zhang
article en
11 citations

Abstract

Cuff-less methods, especially pulse wave analysis (PWA) techniques with PPG/mmWave sensing, have shown great potential for non-intrusive blood pressure (BP) monitoring. However, the state-of-the-art solutions are only validated on small-scale healthy subjects, neglecting patients with abnormal BP and thus a more urgent need for BP monitoring. To bridge the gap, we first build the largest mmWave-BP dataset to our knowledge, including 930 real patients with cardiovascular diseases, and perform extensive experiments, which reveals that all existing PWA methods exhibit far less satisfactory performance with standard deviation errors (STD) exceeding 16 mmHg for systolic BP (SBP) and 11mmHg for diastolic BP (DBP). An in-depth investigation shows that physiological factors have complex effect on vascular elasticity and structure, thus people with very different BP values may exhibit extremely similar pulse waveform, which leads to confusion in model learning. In this work, we propose BP3, which fuses physiological factors into sensing-data-driven deep-learning framework, so as to capture the intricate effect of physiological factors during the whole process of learning pulse waveforms. Evaluation results show that BP3 achieves the mean errors of-1.57 mmHg and -0.34 mmHg, STD of 9.77 mmHg and 7.93 mmHg for SBP and DBP, respectively. Moreover importantly, BP3 shows remarkable gain particularly for subjects with abnormal BP, achieving mean errors that are only 0.48% ~ 20.86% of the state-of-the-art solutions.

Beijing University of Posts and Telecommunications (CN), Hong Kong University of Science and Technology (HK), Peking University (CN), Peking University Third Hospital (CN), University of Hong Kong (HK)
Openalex Percentile: Top 13%
Non-Invasive Vital Sign Monitoring
2.03
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.