CMC/Gel/GO 3D-printed cardiac patches: GO and CMC improve flexibility and promote H9C2 cell proliferation, while EDC/NHS enhances stability

In this research, carboxymethyl cellulose (CMC)/gelatin (Gel)/graphene oxide (GO)-based scaffolds were produced by using extrusion-based 3D printing for cardiac tissue regeneration. Rheological studies were conducted to evaluate the printability of CMC/Gel/GO inks, which revealed that CMC increased viscosity and enhanced printability. The 3D-printed cardiac patches were crosslinked with N-(3-dimethylaminopropyl)-n'-ethylcarbodiimide hydrochloride (EDC)/N-hydroxysuccinimide (NHS) (100:20 mM, 50:10 mM, 25:5 mM) and then characterized by mechanical analysis, electrical conductivity testing, contact angle measurements and degradation studies. Subsequently, cell culture studies were conducted to evaluate the viability of H9C2 cardiomyoblast cells by using the Alamar Blue assay and fluorescence imaging. A high concentration of EDC/NHS (100:20 mM) led to the stability of the patches; however, it drastically reduced the flexibility of the scaffolds. Conversely, a concentration of 25:5 mM resulted in flexible but unstable scaffolds in phosphate buffer saline solution. The suitable EDC/NHS concentration was found to be 50:10 mM, as it produced flexible, stable, and stiff cardiac scaffolds with high ultimate tensile strength. Mechanical characterization revealed that % strain at break of C15/G7.5/GO1 exhibited a remarkable increase of 61.03% compared to C15/G7.5 samples. The improvement of flexibility was attributed to the hydrogen bonding between CMC, Gel and GO. The electrical conductivity of 3D printed CMC/Gel/GO cardiac patches was 7.0 × 10<sup>-3</sup>S cm<sup>-1</sup>, demonstrating suitability for mimicking the desired electrical conductivity of human myocardium. The incorporation of 1 wt% of GO and addition of CMC concentration from 7.5 wt% to 15 wt% significantly enhanced relative % cell viability. Overall, although this research is at its infancy, CMC/Gel/GO cardiac patches have potential to improve the physiological function of cardiac tissue.

Authors

Institutions

Publication Details

Journal
Biofabrication
Published
2024-11-04
DOI
https://doi.org/10.1088/1758-5090/ad8e87
Citations
11
Primary Topic
Tissue Engineering and Regenerative Medicine
Type
article
Field-Weighted Citation Impact
6.30

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

CMC/Gel/GO 3D-printed cardiac patches: GO and CMC improve flexibility and promote H9C2 cell proliferation, while EDC/NHS enhances stability

Duygu Ege, Şule Arıcı, Ali Reza Kamali
11 citations
Biofabrication
Tissue Engineering and Regenerative Medicine
6.30
article

CMC/Gel/GO 3D-printed cardiac patches: GO and CMC improve flexibility and promote H9C2 cell proliferation, while EDC/NHS enhances stability

Duygu Ege, Şule Arıcı, Ali Reza Kamali
article en
11 citations

Abstract

In this research, carboxymethyl cellulose (CMC)/gelatin (Gel)/graphene oxide (GO)-based scaffolds were produced by using extrusion-based 3D printing for cardiac tissue regeneration. Rheological studies were conducted to evaluate the printability of CMC/Gel/GO inks, which revealed that CMC increased viscosity and enhanced printability. The 3D-printed cardiac patches were crosslinked with N-(3-dimethylaminopropyl)-n'-ethylcarbodiimide hydrochloride (EDC)/N-hydroxysuccinimide (NHS) (100:20 mM, 50:10 mM, 25:5 mM) and then characterized by mechanical analysis, electrical conductivity testing, contact angle measurements and degradation studies. Subsequently, cell culture studies were conducted to evaluate the viability of H9C2 cardiomyoblast cells by using the Alamar Blue assay and fluorescence imaging. A high concentration of EDC/NHS (100:20 mM) led to the stability of the patches; however, it drastically reduced the flexibility of the scaffolds. Conversely, a concentration of 25:5 mM resulted in flexible but unstable scaffolds in phosphate buffer saline solution. The suitable EDC/NHS concentration was found to be 50:10 mM, as it produced flexible, stable, and stiff cardiac scaffolds with high ultimate tensile strength. Mechanical characterization revealed that % strain at break of C15/G7.5/GO1 exhibited a remarkable increase of 61.03% compared to C15/G7.5 samples. The improvement of flexibility was attributed to the hydrogen bonding between CMC, Gel and GO. The electrical conductivity of 3D printed CMC/Gel/GO cardiac patches was 7.0 × 10<sup>-3</sup>S cm<sup>-1</sup>, demonstrating suitability for mimicking the desired electrical conductivity of human myocardium. The incorporation of 1 wt% of GO and addition of CMC concentration from 7.5 wt% to 15 wt% significantly enhanced relative % cell viability. Overall, although this research is at its infancy, CMC/Gel/GO cardiac patches have potential to improve the physiological function of cardiac tissue.

BiofabricationVol. 17(1)
Üsküdar University (TR), Kandilli Observatory and Earthquake Research Institute (TR), Boğaziçi University (TR), Northeastern University (CN)
Boğaziçi Üniversitesi
Openalex Percentile: Top 3%
Tissue Engineering and Regenerative Medicine
6.30
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.