High-Load Operating Characteristics of Planar Membrane Humidifiers of Polymer Electrolyte Membrane Fuel Cell Systems for Heavy-Duty Applications

<div class="section abstract"><div class="htmlview paragraph">To gain high efficiencies and long lifetimes, polymer electrolyte membrane fuel cell systems require precise control of the relative humidity of the cathode supply air. This is usually achieved by the use of membrane humidifiers. These are passive components that transfer the product water of the cathode exhaust air to humidify the supply air. Due to the passive design, controllability is achieved via a bypass. It is possible to use map-based control strategies to avoid the use of humidity sensors. Such map-based control requires deep insights into the humidifier behavior in all possible thermodynamic operating states, including various water loads. This paper focuses on typical operating conditions of heavy-duty application at high load, specifically on the occurrence of liquid water in the cathode exhaust gas, which has not been sufficiently investigated in the literature yet. In order to simulate these conditions, we built a test rig with an optically accessible single-channel set-up of a humidifier. We used a perfluorosulfonic acid membrane without a gas diffusion layer. It was shown that condensed liquid fractions, even isolated droplets, at the cathode outlet significantly enhance the water transfer. The influence of water mass flow rate, pressure level, temperature, and gas flow rate on humidifier’s water transfer rate was investigated. Static and dynamic measurements were obtained, with the presence of droplets also leading to characteristic enhancements in mass transfer during dynamic operation. The analyzed data show that if liquid water is not taken into account: a) the risks of flooding, which lead to irreversible ageing processes and thus to permanent performance loss of the fuel cell are not identified and b) opportunities to improve the membrane humidifier in terms of design, operating strategies and model-based control strategies in heavy-duty applications remain unused.</div></div>

Authors

Institutions

Publication Details

Journal
SAE technical papers on CD-ROM/SAE technical paper series
Published
2024-11-04
DOI
https://doi.org/10.4271/2024-01-4323
Citations
1
Primary Topic
Fuel Cells and Related Materials
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-Load Operating Characteristics of Planar Membrane Humidifiers of Polymer Electrolyte Membrane Fuel Cell Systems for Heavy-Duty Applications

Lukas Weiß, Michael Wensing, S. Mull
1 citations
SAE technical papers on CD-ROM/SAE technical paper series
Fuel Cells and Related Materials
0.21
article

High-Load Operating Characteristics of Planar Membrane Humidifiers of Polymer Electrolyte Membrane Fuel Cell Systems for Heavy-Duty Applications

Lukas Weiß, Michael Wensing, S. Mull
article en
1 citations

Abstract

<div class="section abstract"><div class="htmlview paragraph">To gain high efficiencies and long lifetimes, polymer electrolyte membrane fuel cell systems require precise control of the relative humidity of the cathode supply air. This is usually achieved by the use of membrane humidifiers. These are passive components that transfer the product water of the cathode exhaust air to humidify the supply air. Due to the passive design, controllability is achieved via a bypass. It is possible to use map-based control strategies to avoid the use of humidity sensors. Such map-based control requires deep insights into the humidifier behavior in all possible thermodynamic operating states, including various water loads. This paper focuses on typical operating conditions of heavy-duty application at high load, specifically on the occurrence of liquid water in the cathode exhaust gas, which has not been sufficiently investigated in the literature yet. In order to simulate these conditions, we built a test rig with an optically accessible single-channel set-up of a humidifier. We used a perfluorosulfonic acid membrane without a gas diffusion layer. It was shown that condensed liquid fractions, even isolated droplets, at the cathode outlet significantly enhance the water transfer. The influence of water mass flow rate, pressure level, temperature, and gas flow rate on humidifier’s water transfer rate was investigated. Static and dynamic measurements were obtained, with the presence of droplets also leading to characteristic enhancements in mass transfer during dynamic operation. The analyzed data show that if liquid water is not taken into account: a) the risks of flooding, which lead to irreversible ageing processes and thus to permanent performance loss of the fuel cell are not identified and b) opportunities to improve the membrane humidifier in terms of design, operating strategies and model-based control strategies in heavy-duty applications remain unused.</div></div>

SAE technical papers on CD-ROM/SAE technical paper seriesVol. 1
Friedrich-Alexander-Universität Erlangen-Nürnberg (DE)
Clean water and sanitation
Openalex Percentile: Top 46%
Fuel Cells and Related Materials
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.