Applicability assessment of equivalent circuit-thermal coupling models on LiFePO4 batteries operated under wide-temperature and high-rate pulse discharge conditions

In military scenario, high-power lithium iron phosphate (LFP) batteries are frequently used under wide-temperature and high-rate pulse discharge conditions. An accurate electro-thermal coupling model (ETCM) is crucial for the safe operations. Equivalent circuit-thermal coupling model (ECTCM), which combines equivalent circuit model (ECM) and lumped thermal model, is the most widely used type of ETCM in applications. However, the applicability of ECTCM under wide-temperature and high-rate pulse discharge conditions is not clear. To assess the applicability of ECTCM under these special conditions, this study establishes six typical ECTCMs and accurately identify their corresponding model parameters. Then, these models are tested under high-rate pulse discharge conditions from -40 o C to 50 o C. The results indicate that ECTCMs are effective for pulse discharge at ambient and high temperatures, but not suitable for low-temperature conditions below 0 o C. When the temperature is below 0 o C, the pulse discharge voltage of the batteries can not be accurately simulated by ECTCMs. This work provides guidance for electro-thermal coupling modeling under high-rate pulse discharge conditions, and also points out the direction for the development of high-precision ETCM capable of handling wide-temperature and high-rate pulse discharge in the future. • Six ECTCMs are adopted and compared in this study. • Voltage and temperature are utilized to verify the applicability and boundary of the ECTCMs. • Below 0°C, all ECTCMs fail to accurately describe the voltage dynamic response of the LFP batteries under the special working conditions. • Above 20°C, the ECTCMs without hysteresis terms are more suitable for high-rate pulse discharge conditions.

Authors

Institutions

Publication Details

Journal
Energy
Published
2024-11-05
DOI
https://doi.org/10.1016/j.energy.2024.133709
Citations
5
Primary Topic
Advanced Battery Technologies Research
Type
article
Field-Weighted Citation Impact
1.02

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Applicability assessment of equivalent circuit-thermal coupling models on LiFePO4 batteries operated under wide-temperature and high-rate pulse discharge conditions

Yukang Xiao, Zhou Chen, Yajie Liu, Xing Zhou et al.
5 citations
Energy
Advanced Battery Technologies Research
1.02
article

Applicability assessment of equivalent circuit-thermal coupling models on LiFePO4 batteries operated under wide-temperature and high-rate pulse discharge conditions

Yukang Xiao, Zhou Chen, Yajie Liu, Xing Zhou, Yu Wang
article en
5 citations

Abstract

In military scenario, high-power lithium iron phosphate (LFP) batteries are frequently used under wide-temperature and high-rate pulse discharge conditions. An accurate electro-thermal coupling model (ETCM) is crucial for the safe operations. Equivalent circuit-thermal coupling model (ECTCM), which combines equivalent circuit model (ECM) and lumped thermal model, is the most widely used type of ETCM in applications. However, the applicability of ECTCM under wide-temperature and high-rate pulse discharge conditions is not clear. To assess the applicability of ECTCM under these special conditions, this study establishes six typical ECTCMs and accurately identify their corresponding model parameters. Then, these models are tested under high-rate pulse discharge conditions from -40 o C to 50 o C. The results indicate that ECTCMs are effective for pulse discharge at ambient and high temperatures, but not suitable for low-temperature conditions below 0 o C. When the temperature is below 0 o C, the pulse discharge voltage of the batteries can not be accurately simulated by ECTCMs. This work provides guidance for electro-thermal coupling modeling under high-rate pulse discharge conditions, and also points out the direction for the development of high-precision ETCM capable of handling wide-temperature and high-rate pulse discharge in the future. • Six ECTCMs are adopted and compared in this study. • Voltage and temperature are utilized to verify the applicability and boundary of the ECTCMs. • Below 0°C, all ECTCMs fail to accurately describe the voltage dynamic response of the LFP batteries under the special working conditions. • Above 20°C, the ECTCMs without hysteresis terms are more suitable for high-rate pulse discharge conditions.

EnergyVol. 313
National University of Defense Technology (CN)
National Natural Science Foundation of China, Science and Technology Program of Hunan Province
Responsible consumption and production
Openalex Percentile: Top 24%
Advanced Battery Technologies Research
1.02
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.