The role of femoral head size in metal-on-metal hip arthroplasty: analysis of a cohort of 3813 patients with long term follow-up

Metal-on-metal (MoM) large headed arthroplasties were suggested to decrease failure rates by means of reduced volumetric wear and enhanced implant stability. However, they caused high rates of revisions due to adverse reaction to metal debris, osteolysis, pseudotumor growth, and other issues. The study aims to present the long-term outcomes of MoM arthroplasties on a large cohort of patients, evaluating the impact of head sizes on survival rate. All data were retrieved from the regional joint register (Registro dell'Implantologia Protesica Ortopedica, RIPO, Italy). We include in the study all patient who underwent cementless MoM total hip arthroplasties (THAs) between 2000 and 2020, dividing them in two subgroups according to head size (<36 mm, ≥36 mm). Failures were recorded up to December 31, 2020. Patients lost to follow-up were excluded. A total of 3813 THAs met the inclusion/exclusion criteria. The average follow-up period is 12.4 years (0-21 years). 178/1625 (or 11.0%) small head MoM THAs and 265/2188 large head ones failed by the end of follow up. Large diameter heads reported lower survival rate (p-value < 0.001), with unexpected higher dislocation rate (1.0 vs. 0.4%). Moreover, large head size was found to increases the risk of metallosis (p-value < 0.0001). Gender, patient's age and the use of modular neck were not correlated with higher failure rates. MoM implants implants do not have the same reliability as other couplings, considering the significantly greater failure/complication rates. However, the knowledge of risks linked to head size is fundamental for establishing the right type of follow-up to the patient and recognize any complications early.

Authors

Institutions

Publication Details

Journal
Archives of Orthopaedic and Trauma Surgery
Published
2024-11-05
DOI
https://doi.org/10.1007/s00402-024-05567-0
Citations
3
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
1.72

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The role of femoral head size in metal-on-metal hip arthroplasty: analysis of a cohort of 3813 patients with long term follow-up

Fabrizio Quattrini, Corrado Ciatti, Barbara Bordini, Luca Andriollo et al.
3 citations
Archives of Orthopaedic and Trauma Surgery
Orthopaedic implants and arthroplasty
1.72
article

The role of femoral head size in metal-on-metal hip arthroplasty: analysis of a cohort of 3813 patients with long term follow-up

Fabrizio Quattrini, Corrado Ciatti, Barbara Bordini, Luca Andriollo, Monica Cosentino, Chiara Asti, Davide Morsia
article en
3 citations

Abstract

Metal-on-metal (MoM) large headed arthroplasties were suggested to decrease failure rates by means of reduced volumetric wear and enhanced implant stability. However, they caused high rates of revisions due to adverse reaction to metal debris, osteolysis, pseudotumor growth, and other issues. The study aims to present the long-term outcomes of MoM arthroplasties on a large cohort of patients, evaluating the impact of head sizes on survival rate. All data were retrieved from the regional joint register (Registro dell'Implantologia Protesica Ortopedica, RIPO, Italy). We include in the study all patient who underwent cementless MoM total hip arthroplasties (THAs) between 2000 and 2020, dividing them in two subgroups according to head size (<36 mm, ≥36 mm). Failures were recorded up to December 31, 2020. Patients lost to follow-up were excluded. A total of 3813 THAs met the inclusion/exclusion criteria. The average follow-up period is 12.4 years (0-21 years). 178/1625 (or 11.0%) small head MoM THAs and 265/2188 large head ones failed by the end of follow up. Large diameter heads reported lower survival rate (p-value < 0.001), with unexpected higher dislocation rate (1.0 vs. 0.4%). Moreover, large head size was found to increases the risk of metallosis (p-value < 0.0001). Gender, patient's age and the use of modular neck were not correlated with higher failure rates. MoM implants implants do not have the same reliability as other couplings, considering the significantly greater failure/complication rates. However, the knowledge of risks linked to head size is fundamental for establishing the right type of follow-up to the patient and recognize any complications early.

Archives of Orthopaedic and Trauma SurgeryVol. 144(11)
Università Cattolica del Sacro Cuore (IT), University of Parma (IT), Austrian Research Institute for Artificial Intelligence (AT), Istituto Ortopedico Rizzoli (IT), Guglielmo da Saliceto Hospital (IT), Fondazione Poliambulanza Istituto Ospedaliero (IT)
Università degli Studi di Parma
Reduced inequalities
Openalex Percentile: Top 14%
Orthopaedic implants and arthroplasty
1.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.