Metodología para la validación de programas de cálculo de dosis en piel

Objective. A methodology for facilitating the validation of skin dose estimation programs for interventional procedures is presented. Materials and methods. The methodology uses a series of irradiations stored as DICOM Radiation Dose Structured Reports (RDSRs) as well as reference skin dose values measured in each irradiation. Users must input the RDSRs to their program and compare output doses with reference doses. The authors performed 27 irradiations using two C-arms from different manufacturers. For each irradiation, the authors modified parameters that affect skin dose and measured it with an ionization chamber placed under a water phantom. The methodology was applied to validate the program SkinDose 2D. Results. Experimental measurements have an uncertainty of 13% (k=2). SkinDose 2D dose predictions differ from measurements in -9% to +8%, within experimental uncertainty. Conclusions. Varying different parameters that affect skin dose, this methodology allows for an initial validation of skin dose programs, characterizing them before any other additional measurement done by the user.

Authors

Institutions

Publication Details

Journal
Revista de Física Médica
Published
2024-11-04
DOI
https://doi.org/10.37004/sefm/2024.25.2.002
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Metodología para la validación de programas de cálculo de dosis en piel

Roberto Sánchez, J. Fernández, Antonio Gañán Mora
Revista de Física Médica
Radiation Dose and Imaging
article

Metodología para la validación de programas de cálculo de dosis en piel

Roberto Sánchez, J. Fernández, Antonio Gañán Mora
article en

Abstract

Objective. A methodology for facilitating the validation of skin dose estimation programs for interventional procedures is presented. Materials and methods. The methodology uses a series of irradiations stored as DICOM Radiation Dose Structured Reports (RDSRs) as well as reference skin dose values measured in each irradiation. Users must input the RDSRs to their program and compare output doses with reference doses. The authors performed 27 irradiations using two C-arms from different manufacturers. For each irradiation, the authors modified parameters that affect skin dose and measured it with an ionization chamber placed under a water phantom. The methodology was applied to validate the program SkinDose 2D. Results. Experimental measurements have an uncertainty of 13% (k=2). SkinDose 2D dose predictions differ from measurements in -9% to +8%, within experimental uncertainty. Conclusions. Varying different parameters that affect skin dose, this methodology allows for an initial validation of skin dose programs, characterizing them before any other additional measurement done by the user.

Revista de Física MédicaVol. 25(2)
Hospital Clínico San Carlos (ES), Instituto de Investigación Sanitaria del Hospital Clínico San Carlos (ES)
Clean water and sanitation
Openalex Percentile: Top 67%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.