Non-destructive imaging of internal structures of a mosquito with sub-micrometer resolution

Inline x-ray phase tomography has emerged as one of the most suitable imaging techniques for the three-dimensional examination of soft tissue at the microscopic level. Historically, this method was constrained to synchrotron radiation due to its specific requirements, such as beam coherence. However, recent advancements in detector technology (optical magnification) and x-ray sources (e.g., smaller source sizes and liquid metal sources) have enabled the transfer of this technology to laboratory settings. In this study, we investigated selected parts of an ethanol-fixated mosquito—specifically the head, abdomen, and proboscis—at the sub-cellular level using the Xradia 610 Versa (Carl Zeiss X-ray Microscopy, Inc., Dublin, California, United States) with voxel sizes as small as 180nm. A single lens of the compound eye was segmented from the data set of the head, and the focal length was calculated to be 22μm. These results demonstrate the capability of laboratory-based x-ray phase tomography for high-resolution imaging of soft tissues, facilitating detailed structural analyses previously achievable only with synchrotron radiation.

Authors

Institutions

Publication Details

Published
2024-11-04
DOI
https://doi.org/10.1117/12.3029450
Primary Topic
Force Microscopy Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Non-destructive imaging of internal structures of a mosquito with sub-micrometer resolution

G. V. Schulz, Bert Müller, Hans Deyhle, Elena Spörri et al.
Force Microscopy Techniques and Applications
article

Non-destructive imaging of internal structures of a mosquito with sub-micrometer resolution

G. V. Schulz, Bert Müller, Hans Deyhle, Elena Spörri, Martin Gschwind
article en

Abstract

Inline x-ray phase tomography has emerged as one of the most suitable imaging techniques for the three-dimensional examination of soft tissue at the microscopic level. Historically, this method was constrained to synchrotron radiation due to its specific requirements, such as beam coherence. However, recent advancements in detector technology (optical magnification) and x-ray sources (e.g., smaller source sizes and liquid metal sources) have enabled the transfer of this technology to laboratory settings. In this study, we investigated selected parts of an ethanol-fixated mosquito—specifically the head, abdomen, and proboscis—at the sub-cellular level using the Xradia 610 Versa (Carl Zeiss X-ray Microscopy, Inc., Dublin, California, United States) with voxel sizes as small as 180nm. A single lens of the compound eye was segmented from the data set of the head, and the focal length was calculated to be 22μm. These results demonstrate the capability of laboratory-based x-ray phase tomography for high-resolution imaging of soft tissues, facilitating detailed structural analyses previously achievable only with synchrotron radiation.

Swiss Tropical and Public Health Institute (CH), University of Basel (CH)
Openalex Percentile: Top 82%
Force Microscopy Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.