Impact of light polarization on laser speckle contrast imaging with a custom phantom for microvascular flow

Laser speckle contrast imaging (LSCI) is a non-invasive, powerful, and cost-effective imaging technique that has seen widespread adoption across various medical fields, particularly for blood flow imaging. While LSCI provides physicians with valuable insights into changes or occlusions in blood flow, the technique is susceptible to various factors and parameters that can impact measurement sensitivity and signal-to-noise ratio (SNR). These include the scattering of light, which can affect the quality and reliability of the LSCI data. The polarization of light holds significant promise to enhance the performance of LSCI. In this study, we employed polarization manipulation of light to investigate its impact on the performance of LSCI for measuring flow. Focusing on the application of LSCI in microcirculation within capillaries, we examined the effect of polarization control on the technique's flow measurement capabilities using a custom-designed phantom system. This phantom consisted of three tubes with inner diameters of 1.1 mm, 1.6 mm, and 2.8 mm, embedded in a polydimethylsiloxane (PDMS) matrix with optical properties similar to biological tissue. By manipulating the polarization of both the incident and reflected light, alternating between parallel and perpendicular states, we compared the performance of our LSCI system in detecting flow for different tube diameters and depths within the phantom. Our study revealed that while depth is a critical parameter influencing flow detection using LSCI, employing perpendicular polarization (between incident and reflected light) resulted in the lowest measurement error and highest SNR compared to parallel polarization and the absence of polarization control.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2024-11-04
DOI
https://doi.org/10.1038/s41598-024-73757-2
Citations
6
Primary Topic
Thermoregulation and physiological responses
Type
article
Field-Weighted Citation Impact
1.96

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of light polarization on laser speckle contrast imaging with a custom phantom for microvascular flow

Ali Esteki, Mohsen Ahmadi, Pezhman Sasanpour, Nasrin Amini
6 citations
Scientific Reports
Thermoregulation and physiological responses
1.96
article

Impact of light polarization on laser speckle contrast imaging with a custom phantom for microvascular flow

Ali Esteki, Mohsen Ahmadi, Pezhman Sasanpour, Nasrin Amini
article en
6 citations

Abstract

Laser speckle contrast imaging (LSCI) is a non-invasive, powerful, and cost-effective imaging technique that has seen widespread adoption across various medical fields, particularly for blood flow imaging. While LSCI provides physicians with valuable insights into changes or occlusions in blood flow, the technique is susceptible to various factors and parameters that can impact measurement sensitivity and signal-to-noise ratio (SNR). These include the scattering of light, which can affect the quality and reliability of the LSCI data. The polarization of light holds significant promise to enhance the performance of LSCI. In this study, we employed polarization manipulation of light to investigate its impact on the performance of LSCI for measuring flow. Focusing on the application of LSCI in microcirculation within capillaries, we examined the effect of polarization control on the technique's flow measurement capabilities using a custom-designed phantom system. This phantom consisted of three tubes with inner diameters of 1.1 mm, 1.6 mm, and 2.8 mm, embedded in a polydimethylsiloxane (PDMS) matrix with optical properties similar to biological tissue. By manipulating the polarization of both the incident and reflected light, alternating between parallel and perpendicular states, we compared the performance of our LSCI system in detecting flow for different tube diameters and depths within the phantom. Our study revealed that while depth is a critical parameter influencing flow detection using LSCI, employing perpendicular polarization (between incident and reflected light) resulted in the lowest measurement error and highest SNR compared to parallel polarization and the absence of polarization control.

Scientific ReportsVol. 14(1)
Institute for Research in Fundamental Sciences (IR), Shahid Beheshti University of Medical Sciences (IR)
Shahid Beheshti University of Medical Sciences, School of Medicine, Shahid Beheshti University of Medical Sciences
Openalex Percentile: Top 13%
Thermoregulation and physiological responses
1.96
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.