Establishment of ductile fracture locus of 2219 aluminum alloy at cryogenic temperature

Abstract Cryogenic forming has been used to manufacture intricate curved surface aluminum components. The special geometry and mold constraints cause the stress state to continuously evolve. Coupling with the cryogenic temperature makes the deformation process more complicated. Especially for the final fracture, which greatly determines the forming quality of the components. Thus, the cryogenic fracture behavior of three typical stress states was obtained by conducting tensile experiments. Fracture strains and stress paths were obtained using a hybrid numerical-experimental method. Finally, the cryogenic fracture locus was obtained based on the MMC ductile fracture criterion. The results indicate that the AA2219-O exhibits superior ductile fracture properties at cryogenic temperature. The fracture strain of AA2219-O was increased by 52.6% at the uniaxial tensile stress state, and by up to 80.0% at under plane strain stress state. This research has a guiding significance for cryogenic forming.

Authors

Institutions

Publication Details

Journal
Journal of Physics Conference Series
Published
2024-10-01
DOI
https://doi.org/10.1088/1742-6596/2879/1/012044
Primary Topic
Metallurgy and Material Forming
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Establishment of ductile fracture locus of 2219 aluminum alloy at cryogenic temperature

Fangxing Wu, Xiaobo Fan, Tongliang Du, Zhichao Zhang et al.
Journal of Physics Conference Series
Metallurgy and Material Forming
article

Establishment of ductile fracture locus of 2219 aluminum alloy at cryogenic temperature

Fangxing Wu, Xiaobo Fan, Tongliang Du, Zhichao Zhang, Qiwei Hu
article en

Abstract

Abstract Cryogenic forming has been used to manufacture intricate curved surface aluminum components. The special geometry and mold constraints cause the stress state to continuously evolve. Coupling with the cryogenic temperature makes the deformation process more complicated. Especially for the final fracture, which greatly determines the forming quality of the components. Thus, the cryogenic fracture behavior of three typical stress states was obtained by conducting tensile experiments. Fracture strains and stress paths were obtained using a hybrid numerical-experimental method. Finally, the cryogenic fracture locus was obtained based on the MMC ductile fracture criterion. The results indicate that the AA2219-O exhibits superior ductile fracture properties at cryogenic temperature. The fracture strain of AA2219-O was increased by 52.6% at the uniaxial tensile stress state, and by up to 80.0% at under plane strain stress state. This research has a guiding significance for cryogenic forming.

Journal of Physics Conference SeriesVol. 2879(1)
Dalian University of Technology (CN), Shanghai Aerospace Automobile Electromechanical (China) (CN)
Openalex Percentile: Top 79%
Metallurgy and Material Forming
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Establishment of ductile fracture locus of 2219 aluminum alloy at cryogenic temperature — Fangxing Wu, Xiaobo Fan, et al. · Journal of Physics Conference Series (2024) | TGRS Research Map | TGRS