Evaluation of electrognathography indicators in patients with decreased height of the lower part of the face and symptoms of intolerance to the structural materials of dentures

Purpose of the study: to conduct a comparative assessment of electrognathography indices in elderly patients with a decrease in the height of the lower part of the face with symptoms characteristic of intolerance to the structural materials of dentures, before and during the diagnostic and treatment stages of using occlusal-stabilizing devices. Material and methods. We examined 76 patients aged 61 to 74 years with a decrease in the height of the lower part of the face and the presence of symptoms characteristic of intolerance to the structural materials of dentures. Based on the results of a short “Hamburg” examination, 30 patients were selected with the possibility of dysfunctional disorders of the temporomandibular joint, for whom occlusal-stabilizing devices were made. Results. A study of elderly patients with a decrease in the height of the lower part of the face and symptoms characteristic of intolerance to the structural materials of dentures revealed the effectiveness of the use of occlusal-stabilizing devices at the treatment and diagnostic stages due to a decrease in complaints of dry mouth more than in twice, a decrease in the intensity of burning of the mucous membrane, a decrease in the number of complaints accompanying dysfunctional disorders of the temporomandibular joint, as well as an improvement in electrognathography indicators to physiological norms. Conclusion. The obtained results of treatment with occlusal-stabilizing devices for patients with a decrease in the height of the lower part of the face, presenting complaints characteristic of intolerance to the structural materials of dentures, at the treatment and diagnostic stages indicate the feasibility and effectiveness of their use in this category of people.

Authors

Publication Details

Journal
Medical alphabet
Published
2024-11-02
DOI
https://doi.org/10.33667/2078-5631-2024-18-96-99
Primary Topic
Myofascial pain diagnosis and treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of electrognathography indicators in patients with decreased height of the lower part of the face and symptoms of intolerance to the structural materials of dentures

O. I. Manin, Л. В. Дубова, A. M. Rudakova, R. V. Samoylenko
Medical alphabet
Myofascial pain diagnosis and treatment
article

Evaluation of electrognathography indicators in patients with decreased height of the lower part of the face and symptoms of intolerance to the structural materials of dentures

O. I. Manin, Л. В. Дубова, A. M. Rudakova, R. V. Samoylenko
article en

Abstract

Purpose of the study: to conduct a comparative assessment of electrognathography indices in elderly patients with a decrease in the height of the lower part of the face with symptoms characteristic of intolerance to the structural materials of dentures, before and during the diagnostic and treatment stages of using occlusal-stabilizing devices. Material and methods. We examined 76 patients aged 61 to 74 years with a decrease in the height of the lower part of the face and the presence of symptoms characteristic of intolerance to the structural materials of dentures. Based on the results of a short “Hamburg” examination, 30 patients were selected with the possibility of dysfunctional disorders of the temporomandibular joint, for whom occlusal-stabilizing devices were made. Results. A study of elderly patients with a decrease in the height of the lower part of the face and symptoms characteristic of intolerance to the structural materials of dentures revealed the effectiveness of the use of occlusal-stabilizing devices at the treatment and diagnostic stages due to a decrease in complaints of dry mouth more than in twice, a decrease in the intensity of burning of the mucous membrane, a decrease in the number of complaints accompanying dysfunctional disorders of the temporomandibular joint, as well as an improvement in electrognathography indicators to physiological norms. Conclusion. The obtained results of treatment with occlusal-stabilizing devices for patients with a decrease in the height of the lower part of the face, presenting complaints characteristic of intolerance to the structural materials of dentures, at the treatment and diagnostic stages indicate the feasibility and effectiveness of their use in this category of people.

Medical alphabet(18)
Good health and well-being
Openalex Percentile: Top 80%
Myofascial pain diagnosis and treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.