Smartphone Proprioception for Ankle Navigation (SPAN): Reliability and Effect of Position Exposure Time

This study investigated ankle discriminative acuity and performance and measurement consistency for tests undertaken with different joint position exposure times (PETs). Twenty-four participants were tested using a novel Smartphone Proprioception for Ankle Navigation (SPAN) under four PETs, i.e., 0.25s, 0.5s, 0.75s and 1s, delivered in a random sequence, and then re-tested within one week. The results indicated a PET main effect (<i>F</i> = 10.12, <i>p</i> = 0.004, partial ƞ2 = 0.14), and limb preference main effect (<i>F</i> = 5.39, <i>p</i> = 0.03, partial ƞ2 = 0.19), without significant interactions (<i>p</i> > 0.05). Ankle proprioception improved with prolonged PET, with the non-dominant side outperforming the dominant side. A PET of 0.25s showed good to excellent reliability, with intraclass correlation coefficients (ICCs) of 0.897 (95%CI: 0.761, 0.955) and 0.885 (95%CI: 0.736, 0.951), with standard errors of measurements (SEM) between 0.030 and 0.035, and minimum detectable change at 90% (MDC<sub>90</sub>) between 0.070 and 0.082, compared to poor to moderate reliability at the other three longer PETs (ICCs =0.352-0.736). The findings suggested the prolongation of PET can improve ankle proprioceptive performance but can amplify the inter-occasion variability, likely due to increased cognitive analysis with longer stimulus sampling. SPAN may thus be a cost-effective and accessible apparatus for clinical practice.

Authors

Institutions

Publication Details

Journal
Journal of Motor Behavior
Published
2024-11-03
DOI
https://doi.org/10.1080/00222895.2024.2416231
Citations
1
Primary Topic
Foot and Ankle Surgery
Type
article
Field-Weighted Citation Impact
0.48
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Smartphone Proprioception for Ankle Navigation (SPAN): Reliability and Effect of Position Exposure Time

Jia Han, Doa El‐Ansary, Charlotte Ganderton, Xiaojian Shi et al.
1 citations
Journal of Motor Behavior
Foot and Ankle Surgery
0.48
article

Smartphone Proprioception for Ankle Navigation (SPAN): Reliability and Effect of Position Exposure Time

Jia Han, Doa El‐Ansary, Charlotte Ganderton, Xiaojian Shi, Oren Tirosh, Roger Adams
article en
1 citations

Abstract

This study investigated ankle discriminative acuity and performance and measurement consistency for tests undertaken with different joint position exposure times (PETs). Twenty-four participants were tested using a novel Smartphone Proprioception for Ankle Navigation (SPAN) under four PETs, i.e., 0.25s, 0.5s, 0.75s and 1s, delivered in a random sequence, and then re-tested within one week. The results indicated a PET main effect (<i>F</i> = 10.12, <i>p</i> = 0.004, partial ƞ2 = 0.14), and limb preference main effect (<i>F</i> = 5.39, <i>p</i> = 0.03, partial ƞ2 = 0.19), without significant interactions (<i>p</i> > 0.05). Ankle proprioception improved with prolonged PET, with the non-dominant side outperforming the dominant side. A PET of 0.25s showed good to excellent reliability, with intraclass correlation coefficients (ICCs) of 0.897 (95%CI: 0.761, 0.955) and 0.885 (95%CI: 0.736, 0.951), with standard errors of measurements (SEM) between 0.030 and 0.035, and minimum detectable change at 90% (MDC<sub>90</sub>) between 0.070 and 0.082, compared to poor to moderate reliability at the other three longer PETs (ICCs =0.352-0.736). The findings suggested the prolongation of PET can improve ankle proprioceptive performance but can amplify the inter-occasion variability, likely due to increased cognitive analysis with longer stimulus sampling. SPAN may thus be a cost-effective and accessible apparatus for clinical practice.

Journal of Motor BehaviorVol. 57(1)
The University of Melbourne (AU), University of Canberra (AU), Shanghai University of Medicine and Health Sciences (CN), Swinburne University of Technology (AU), RMIT University (AU)
Affordable and clean energy
Openalex Percentile: Top 35%
Foot and Ankle Surgery
0.48
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.